EN

Lux, lumens and candelas

Photometric unit converter: area, beam angle and distance

Lux, lumens and candelas cannot be converted directly into one another: they measure different things. To go from one to another you need a geometric figure: the lit area, the beam angle or the distance. This converter has one calculator for each case.

1. Lumens and lux on a surface

Flux spread over a surface
lm
m²

2. Candelas, lumens and beam angle

Spotlight, floodlight or reflector lamp
lm
°
m

The beam is assumed to be uniform inside the cone and zero outside it. In a real spotlight the intensity falls off gradually from the axis, so for the same flux the centre intensity is usually somewhat higher than calculated and the edge of the circle is soft.

3. Other conversions

Units
lx
fc
lm
W

Photometric quantities

QuantitySymbolUnitWhat it measures
Luminous flux\(\Phi\)lumen (lm)The total light emitted by a source in all directions, weighted by the sensitivity of the eye.
Luminous intensity\(I\)candela (cd)The flux leaving in one particular direction, per unit solid angle: 1 cd = 1 lm/sr.
Illuminance\(E\)lux (lx)The flux arriving at a surface, per square metre: 1 lx = 1 lm/m². This is what a lux meter reads.
Luminance\(L\)cd/m²How bright a surface looks from a given direction. It is what the eye perceives and what causes glare.
Luminous efficacy\(\eta\)lm/WThe lumens a source gives for each watt it consumes.

Water makes a useful comparison: flux is the flow coming out of a hose, intensity is the strength of the jet in one direction and illuminance is how much water falls on each square metre of ground. The same flow soaks a small circle (narrow beam) or barely wets a large area (wide beam).

Formulas

From lumens to lux

\[ E = \frac{\Phi \cdot k}{S} \qquad \Phi = \frac{E \cdot S}{k} \]

\(k\) is the share of the flux that actually reaches the surface. Indoors, light is lost on walls, ceiling and in the luminaire itself, so a complete installation is designed with the lumen method, which works out that factor (the utilisation factor) from the room geometry and the reflectance factors.

From candelas to lumens in a conical beam

\[ \Omega = 2\pi\left(1 - \cos\frac{\alpha}{2}\right) \qquad \Phi = I \cdot \Omega \]

\(\Omega\) is the solid angle of the cone, in steradians, and \(\alpha\) its full beam angle. A whole sphere is \(4\pi \approx 12.57\) sr. That is why an 800 lm bulb that shines in every direction gives only about 64 cd, while an 800 lm spotlight with a 24° beam exceeds 5000 cd on its axis.

From candelas to lux: inverse square and cosine laws

\[ E = \frac{I}{d^2} \qquad E_\gamma = \frac{I(\gamma)\cdot\cos\gamma}{d^2} = \frac{I(\gamma)\cdot\cos^3\gamma}{h^2} \]

Illuminance falls with the square of the distance: at twice the distance, a quarter of the lux. If the light arrives tilted by an angle \(\gamma\) from the perpendicular, it spreads over more area and you multiply by \(\cos\gamma\). This is the basis of the point-by-point method. These formulas are exact for sources that are small compared with the distance; as a rule of thumb, from about five times the size of the luminaire.

Diameter of the light circle

\[ D = 2\,d\,\tan\frac{\alpha}{2} \]

Lux and foot-candles

In the United States illuminance is often given in foot-candles (fc), lumens per square foot. Since a square metre is 10.764 square feet, 1 fc = 10.764 lx. An office at 500 lx has about 46 fc.

Reference values

SituationApproximate illuminance
Full-moon night0.1–0.3 lx
Street with public lighting5–30 lx
Corridor or warehouse100–200 lx
Office or classroom300–500 lx
Fine assembly, general operating theatre750–1000 lx
Overcast day outdoors1000–10,000 lx
Direct midday sunup to 100,000 lx

The recommended levels for each type of space are in the lighting levels table.

Luminous efficacy of light sources

SourceTypical efficacy
Standard incandescent10–15 lm/W
Halogen15–25 lm/W
Compact fluorescent50–70 lm/W
T5/T8 fluorescent tube with electronic ballast80–100 lm/W
Metal halide80–110 lm/W
High-pressure sodium90–130 lm/W
LED (current lamp or luminaire)100–200 lm/W

When replacing an old lamp with an LED, compare lumens, not watts: a 60 W incandescent gave about 800 lm, which an LED achieves with 7–9 W. For luminaires, the figure that matters is the flux of the complete luminaire, not that of the bare LEDs, because the diffuser and optics lose part of the light.

Related: lighting calculation, point-by-point method, photometric diagrams and colour temperature.