Photometric unit converter: area, beam angle and distance
Lux, lumens and candelas cannot be converted directly into one another: they measure different things. To go from one to another you need a geometric figure: the lit area, the beam angle or the distance. This converter has one calculator for each case.
The beam is assumed to be uniform inside the cone and zero outside it. In a real spotlight the intensity falls off gradually from the axis, so for the same flux the centre intensity is usually somewhat higher than calculated and the edge of the circle is soft.
| Quantity | Symbol | Unit | What it measures |
|---|---|---|---|
| Luminous flux | \(\Phi\) | lumen (lm) | The total light emitted by a source in all directions, weighted by the sensitivity of the eye. |
| Luminous intensity | \(I\) | candela (cd) | The flux leaving in one particular direction, per unit solid angle: 1 cd = 1 lm/sr. |
| Illuminance | \(E\) | lux (lx) | The flux arriving at a surface, per square metre: 1 lx = 1 lm/m². This is what a lux meter reads. |
| Luminance | \(L\) | cd/m² | How bright a surface looks from a given direction. It is what the eye perceives and what causes glare. |
| Luminous efficacy | \(\eta\) | lm/W | The lumens a source gives for each watt it consumes. |
Water makes a useful comparison: flux is the flow coming out of a hose, intensity is the strength of the jet in one direction and illuminance is how much water falls on each square metre of ground. The same flow soaks a small circle (narrow beam) or barely wets a large area (wide beam).
\(k\) is the share of the flux that actually reaches the surface. Indoors, light is lost on walls, ceiling and in the luminaire itself, so a complete installation is designed with the lumen method, which works out that factor (the utilisation factor) from the room geometry and the reflectance factors.
\(\Omega\) is the solid angle of the cone, in steradians, and \(\alpha\) its full beam angle. A whole sphere is \(4\pi \approx 12.57\) sr. That is why an 800 lm bulb that shines in every direction gives only about 64 cd, while an 800 lm spotlight with a 24° beam exceeds 5000 cd on its axis.
Illuminance falls with the square of the distance: at twice the distance, a quarter of the lux. If the light arrives tilted by an angle \(\gamma\) from the perpendicular, it spreads over more area and you multiply by \(\cos\gamma\). This is the basis of the point-by-point method. These formulas are exact for sources that are small compared with the distance; as a rule of thumb, from about five times the size of the luminaire.
In the United States illuminance is often given in foot-candles (fc), lumens per square foot. Since a square metre is 10.764 square feet, 1 fc = 10.764 lx. An office at 500 lx has about 46 fc.
| Situation | Approximate illuminance |
|---|---|
| Full-moon night | 0.1–0.3 lx |
| Street with public lighting | 5–30 lx |
| Corridor or warehouse | 100–200 lx |
| Office or classroom | 300–500 lx |
| Fine assembly, general operating theatre | 750–1000 lx |
| Overcast day outdoors | 1000–10,000 lx |
| Direct midday sun | up to 100,000 lx |
The recommended levels for each type of space are in the lighting levels table.
| Source | Typical efficacy |
|---|---|
| Standard incandescent | 10–15 lm/W |
| Halogen | 15–25 lm/W |
| Compact fluorescent | 50–70 lm/W |
| T5/T8 fluorescent tube with electronic ballast | 80–100 lm/W |
| Metal halide | 80–110 lm/W |
| High-pressure sodium | 90–130 lm/W |
| LED (current lamp or luminaire) | 100–200 lm/W |
When replacing an old lamp with an LED, compare lumens, not watts: a 60 W incandescent gave about 800 lm, which an LED achieves with 7–9 W. For luminaires, the figure that matters is the flux of the complete luminaire, not that of the bare LEDs, because the diffuser and optics lose part of the light.
Related: lighting calculation, point-by-point method, photometric diagrams and colour temperature.