EN

Photometric diagrams

Polar curve, C-γ system, isocandela, isolux and cone diagram

A luminaire datasheet includes several drawings that describe how it distributes light. Knowing how to read them lets you choose the right luminaire without calculation software: whether the beam is narrow or wide, whether it lights the walls, whether it causes glare or how many lux it will give at a certain height. The simulator draws the three main diagrams for a model luminaire; change its data and watch how they vary.

Simulator

Luminaire
°
%
%
lm
m

Cone diagram

The simulator luminaire is a mathematical model (cosⁿ distribution) that resembles real ones but is not any particular product. For a project always use the manufacturer's photometric data.

The C-γ coordinate system

To describe the direction in which light leaves, a system of vertical planes rotating around the axis of the luminaire is used, like the pages of an open book:

Sports and façade floodlights sometimes use another system, B-β, with its axis in the direction of the beam, because it better describes luminaires installed at a tilt.

The polar distribution curve

This is the most common diagram. It shows the luminous intensity in each direction γ, in one or two C planes, plotted in polar coordinates: the distance from the centre is the intensity. Normally the C0–C180 plane is drawn with a solid line and C90–C270 with a dashed line. If both coincide, the luminaire is symmetrical (rotationally symmetric).

For very narrow-beam floodlights the polar curve would look like a needle that is hard to read, so manufacturers usually give it in Cartesian coordinates: intensity on the vertical axis and angle on the horizontal one.

The isocandela diagram

The polar curve shows only two planes. The isocandela diagram shows every direction at once: it is a map of the sphere around the luminaire in which directions of equal intensity are joined by a line, just as the contour lines of a topographic map join points of equal height. In the simulator the centre is the nadir (γ = 0°), each circle is an angle γ and the direction indicates the C plane.

It is essential for asymmetric luminaires, such as street lights or floodlights, in which the intensity varies greatly from one plane to another. In a symmetrical luminaire the isocandela lines are concentric circles.

Isolux curves

They show the illuminance that the luminaire produces on the horizontal plane (the floor or working plane): each curve joins the points with the same lux. They are calculated from the intensity distribution with the inverse square and cosine laws:

\[ E = \frac{I(C,\gamma)\cdot\cos^3\gamma}{h^2} \]

Street lighting catalogues give isolux curves in relative form (as % of the maximum illuminance, with distances as multiples of the mounting height \(h\)) so the diagram works at any height and flux. Adding the isolux curves of several luminaires gives the lighting of an area: this is the point-by-point method.

The cone diagram

For spotlights and downlights it is the most practical one: for several distances it gives the diameter of the lit circle (with the beam angle) and the illuminance at the centre. It helps choose the spotlight and the height without calculations. The simulator table is a cone diagram for the chosen luminaire and flux.

Other photometric data on the datasheet

Photometric files: EULUMDAT and IES

The diagrams are generated from a table of intensities measured with a goniophotometer, which the manufacturer publishes as a file: EULUMDAT (.ldt), the European format, or IES (.ies), the North American one (ANSI/IES LM-63). Both contain the intensity for a grid of C planes and γ angles. Programs such as DIALux or Relux read these files and use them to calculate the isolux, uniformity and UGR of a complete installation.

Related: point-by-point method, luminaire classification, lux, lumen and candela converter and lighting calculation.