EN

Colour temperature and colour rendering

Kelvin, warm, neutral or cool light, CRI (Ra), R9, TM-30 and SDCM

What colour temperature is

A hot body emits light whose colour depends only on its temperature: red-hot iron is at about 1000 K, a candle flame at about 1900 K, a light bulb filament at about 2700 K and the surface of the Sun at about 5800 K. The correlated colour temperature (CCT) of a source is the temperature, in kelvin, to which that ideal body (the "black body") would have to be heated for its light to have the same tint. Paradoxically, low temperatures give warm (orange) light and high temperatures give cool (bluish) light.

Colour temperature describes only the tint of white light. It says nothing about its quality: two 4000 K lamps can render colours very differently. That is what the colour rendering index, explained below, is for.

Light colour simulator

Colour temperature
K
K

The colour shown is that of the black body at that temperature, adapted to the screen using the sRGB reference white (6500 K). It is an approximation: the screen, its calibration and the adaptation of the eye change the perception, and in a real room the eye adapts and sees almost any light between 2700 and 6500 K as "white" after a few minutes.

Warm, neutral or cool light: which to choose

TintTemperatureFeelTypical uses
Very warm1800–2400 KIntimate, like a candle or a sodium lampDecoration, restaurant ambience, lighting that respects wildlife or observatories
Warm2700–3000 KCosy, relaxingHomes, bedrooms, hotels, restaurants, fashion or furniture shops
Neutral3500–4500 KNatural, balancedOffices, classrooms, shops, hospitals, kitchens, bathrooms, modern street lighting
Cool5000–6500 KActive, technical, similar to daylightIndustry, workshops, laboratories, visual inspection, car parks

The EN 12464-1 standard groups sources into three tints: warm (below 3300 K), intermediate (3300 to 5300 K) and cool (above 5300 K). It does not require any one of them: it is a design choice. Some practical guidelines:

The lamp colour code

Manufacturers state colour quality with three digits: the first is the colour rendering index divided by 10 and the next two are the colour temperature in hundreds of kelvin. For example, 840 means Ra ≥ 80 and 4000 K, and 930 means Ra ≥ 90 and 3000 K. This code appears on fluorescent tubes, LED tubes and the datasheets of many luminaires.

Colour rendering index (CRI or Ra)

It measures how faithfully a light source shows the colours of objects compared with a reference light of the same colour temperature (the black body below 5000 K and daylight above). It is calculated by lighting eight standard colour samples (R1 to R8, pastel colours) with the source and with the reference, and measuring how much each one changes. The general index Ra is the average of the eight, on a scale where 100 is perfect rendering.

Light sourceTypical Ra
Incandescent and halogen100
High-quality LED90–98
Standard LED80–85
Triphosphor fluorescent tube80–89
Metal halide (ceramic)80–95
Old fluorescent tube (halophosphate)50–75
Mercury vapour40–50
High-pressure sodium20–25
Low-pressure sodiumDoes not render colours (monochromatic light)

What Ra each space requires

The minimum values for each specific task are in the lighting levels table, in the Ra column.

The limits of Ra: R9 and TM-30

The eight Ra samples are unsaturated colours, so a source can have a high Ra and still render saturated reds poorly, which is precisely the weak point of many LEDs. That is why the R9 value (saturated red), one of the additional samples of the method, is also checked: an Ra 80 LED usually has R9 between 0 and 20, while an Ra 95 one exceeds 50. For butchers, greengrocers, human skin (hospitals, TV studios) or textiles it is worth asking for R9 > 50.

The IES TM-30 method (also adopted by the CIE as a fidelity index) uses 99 samples of real colours and gives two figures: Rf, fidelity, the modern equivalent of Ra, and Rg, gamut, which shows whether the source saturates colours (Rg > 100) or dulls them (Rg < 100). A colour vector graphic shows which hues shift and in which direction.

Colour consistency between lamps: SDCM

Two LEDs with the same 840 code can have slightly different tints, one a little greenish and the other a little pinkish. The tolerance is expressed in MacAdam ellipse steps (SDCM): at 1 step the difference is imperceptible, at 3 steps it is barely visible when compared closely, and from 5 steps it is clearly noticeable in a row of luminaires. SDCM ≤ 3 is recommended for offices and shops.

Colour temperature, Duv and the Planckian locus

On the CIE chromaticity diagram, black-body colours form a curve, the Planckian locus. Most sources do not fall exactly on it: the CCT is the temperature of the nearest point on the locus, and the distance to the curve is called Duv. With positive Duv the light tends to green and with negative Duv to pink or magenta. Values between −0.006 and +0.006 are considered normal white light.

The mired (micro reciprocal degree), \(10^6/T\), is also used, especially in photography and correction filters: the changes in tint we perceive are more even in mired than in kelvin. Going from 2700 to 3000 K (37 mired) is much more noticeable than going from 6000 to 6500 K (13 mired).

Related: lighting levels and minimum Ra, lux and lumen converter, luminaire classification and lighting calculation.