The number of turns per phase is one of the key parameters of a three-phase motor winding. It directly determines the induced voltage, the magnetic behaviour of the stator and the thermal performance of the motor. Getting the number of turns wrong can cause:
This technical guide explains how to work out the number of turns in theory and how to adjust it in a real rewinding case.
The back-EMF (counter-electromotive force) induced per phase in a three-phase system is given by:
Where:
Solving for N gives the number of turns per phase:
In practice, E is slightly lower than the applied phase voltage because of the drop across the winding resistance and leakage reactance; E ≈ 0.95 · Vphase is a common assumption.
A 4-pole, 400 V star-connected, 50 Hz three-phase motor is to be rewound. Its stator has 36 slots, a bore diameter D = 120 mm and a core length L = 100 mm. We take an average air-gap flux density of 0.6 T and a winding factor kw = 0.96.
If the motor had an original winding, always compare with its data: the number of turns should be similar. For a more accurate calculation, try the turns calculator.
Flux density is the key decision: lower flux density gives more turns, thinner wire and less power; higher flux density gives fewer turns and more power, but more no-load current and more heat in the iron. The turns calculator works with the peak flux density in the air gap, normally between 7000 and 10,000 G on a 4-pole motor. The average flux density in this guide is about 2/π of that peak: 0.6 T average is about 9400 G peak.
Its result is the total number of conductors (6·N). Divide it by the slots to get the turns per coil in single layer. In the example above, 9500 G gives 1082, and 1082 / 36 ≈ 30 turns, the same as with the formula.
Following the example, with 11 A in star and 5 A/mm² you need 2.2 mm². Three 0.95 mm wires add up to 2.13 mm², about 5.2 A/mm². With 30 turns per slot, that is 90 wires in each slot.
If you have the data of the original winding, there is no need to calculate from scratch. For another voltage at the same frequency, the turns change in proportion to the voltage and the section inversely: going from 230 V to 400 V on the coil means about 1.74 times more turns and 1.74 times less section. If the frequency changes at the same voltage, the turns are inversely proportional to the frequency. All the cases, with examples, are in Modifying an induction motor winding.
| Poles | RPM (50 Hz) |
|---|---|
| 2 | 3000 |
| 4 | 1500 |
| 6 | 1000 |
| 8 | 750 |