Calculating the number of turns in a three-phase motor

Introduction

The number of turns per phase is one of the key parameters of a three-phase motor winding. It directly determines the induced voltage, the magnetic behaviour of the stator and the thermal performance of the motor. Getting the number of turns wrong can cause:

This technical guide explains how to work out the number of turns in theory and how to adjust it in a real rewinding case.

Theory

The back-EMF (counter-electromotive force) induced per phase in a three-phase system is given by:

$$ E = 4.44 \cdot f \cdot N \cdot \Phi \cdot k_w $$

Where:

Solving for N gives the number of turns per phase:

$$ N = \frac{E}{4.44 \cdot f \cdot \Phi \cdot k_w} $$

In practice, E is slightly lower than the applied phase voltage because of the drop across the winding resistance and leakage reactance; E ≈ 0.95 · Vphase is a common assumption.

How to calculate the number of turns

Worked example

A 4-pole, 400 V star-connected, 50 Hz three-phase motor is to be rewound. Its stator has 36 slots, a bore diameter D = 120 mm and a core length L = 100 mm. We take an average air-gap flux density of 0.6 T and a winding factor kw = 0.96.

  1. Phase voltage: 400 / √3 ≈ 231 V, so E ≈ 0.95 · 231 ≈ 219 V.
  2. Area of one pole: π · D · L / 2p = π · 0.12 · 0.10 / 4 ≈ 0.00942 m².
  3. Flux per pole: Φ = 0.6 · 0.00942 ≈ 0.00565 Wb.
  4. Turns per phase: N = 219 / (4.44 · 50 · 0.00565 · 0.96) ≈ 182 turns.
  5. With 36 slots in a single-layer winding there are 36 / (2 · 3) = 6 coils per phase, so each coil has 182 / 6 ≈ 30 turns (180 turns per phase).

If the motor had an original winding, always compare with its data: the number of turns should be similar. For a more accurate calculation, try the turns calculator.

What data to record before stripping

Choosing the flux density

Flux density is the key decision: lower flux density gives more turns, thinner wire and less power; higher flux density gives fewer turns and more power, but more no-load current and more heat in the iron. The turns calculator works with the peak flux density in the air gap, normally between 7000 and 10,000 G on a 4-pole motor. The average flux density in this guide is about 2/π of that peak: 0.6 T average is about 9400 G peak.

Its result is the total number of conductors (6·N). Divide it by the slots to get the turns per coil in single layer. In the example above, 9500 G gives 1082, and 1082 / 36 ≈ 30 turns, the same as with the formula.

From the number of turns to the wire

  1. Calculate the current in each phase: in star it is the line current; in delta, the line current divided by 1.73.
  2. Divide by the current density. As a general guide, about 4 to 7 A/mm² is used, less the larger the motor or the poorer its cooling.
  3. If the section comes out large, split it into several wires with IEC equivalences or NEMA equivalences.
  4. Check that it fits with Turns by slot. If it does not, review the flux density or the power you are asking for.

Following the example, with 11 A in star and 5 A/mm² you need 2.2 mm². Three 0.95 mm wires add up to 2.13 mm², about 5.2 A/mm². With 30 turns per slot, that is 90 wires in each slot.

If you change the voltage or keep the winding

If you have the data of the original winding, there is no need to calculate from scratch. For another voltage at the same frequency, the turns change in proportion to the voltage and the section inversely: going from 230 V to 400 V on the coil means about 1.74 times more turns and 1.74 times less section. If the frequency changes at the same voltage, the turns are inversely proportional to the frequency. All the cases, with examples, are in Modifying an induction motor winding.

Reference table

Poles RPM (50 Hz)
2 3000
4 1500
6 1000
8 750
⚠ Technical note: the actual speed is always slightly lower because of the motor's slip.

Common mistakes