Find out the required turns based on slot dimensions
It calculates how many enamelled wires fit in a stator slot according to its shape, its dimensions, the insulation and the wire diameter. It tells you whether a winding is possible before you cut any wire: if the turns you calculated do not fit, you need to change the wire, split it in parallel or review the calculation.
| Shape | Dimensions | What it looks like |
|---|---|---|
| Trapezoidal | h, W, w | W is the width at the bottom and w the width next to the opening. |
| Straight | h, W | Constant width W. Leave w empty. |
| Rounded | h, W | Constant width W with both ends rounded. Leave w empty. |
| Asymmetric rounded | h, W, w | Rounded at both ends, with one end wider (W) than the other (w). |
h is always the total height of the slot. If the lamination is worn or hard to measure, take a template of the slot with card and measure that.
It first gets the slot area and subtracts the paper: perimeter times thickness. It then applies a 75% fill factor and divides by the real area of each wire, adding the enamel with an approximate thickness of 0.012 + 0.022·√d mm per side.
\[ N_{\max} = \frac{0.75\,(A_{\text{slot}} - P \cdot t_{\text{paper}})}{\sum A_{\text{wire}}} \]
A rounded slot with h = 20 mm and W = 8 mm, 0.3 mm paper and 0.80 mm wire: 168 wires fit. If the motor needs 30 turns per slot, you could use up to 168 / 30 = 5 wires in hand, rounding down. That is 2.51 mm² of copper per turn.
To split a section into thinner wires, use IEC equivalences or NEMA equivalences. For the number of turns, use Turns by stator.