Convert sections or gauges into other combinations
It finds combinations of enamelled wire in AWG gauges, in parallel, with the same section as the original gauge. This is what you need if you work to the American standard and do not have the gauge the winding calls for, or if a thick wire does not fit well in the slot.
In AWG, the higher the number, the thinner the wire. A useful rule: every 3 gauges the section roughly halves, so two AWG 21 wires are almost equal to one AWG 18.
\[ d = 0.127 \cdot 92^{(36-n)/39}\ \text{mm} \]
Each row gives the gauges that go together, the section they add up to in mm² and the difference from the target. The table runs from largest to smallest section. If nothing appears, widen the tolerance: consecutive gauges are quite far apart, and 1% usually leaves few options. The search only combines gauges close to each other, within 2 to 5 numbers depending on the section.
An original AWG 18 (0.823 mm²) that you do not have. Exclude it and use a 5% tolerance. The clear option is 21 + 21, with 0.821 mm², just 0.25% less.
| AWG | Diameter (mm) | Section (mm²) |
|---|---|---|
| 14 | 1.628 | 2.081 |
| 16 | 1.291 | 1.309 |
| 18 | 1.024 | 0.823 |
| 20 | 0.812 | 0.518 |
| 21 | 0.723 | 0.410 |
| 22 | 0.644 | 0.326 |
| 23 | 0.573 | 0.258 |
| 24 | 0.511 | 0.205 |
| 25 | 0.455 | 0.162 |
| 26 | 0.405 | 0.129 |
| 28 | 0.321 | 0.081 |
| 30 | 0.255 | 0.051 |