NEMA Conductor Equivalences (AWG)

Convert sections or gauges into other combinations

Operation

Don’t have the original gauges? Use this converter to create equivalent combinations

Input type

Select gauges


What it is for

It finds combinations of enamelled wire in AWG gauges, in parallel, with the same section as the original gauge. This is what you need if you work to the American standard and do not have the gauge the winding calls for, or if a thick wire does not fit well in the slot.

In AWG, the higher the number, the thinner the wire. A useful rule: every 3 gauges the section roughly halves, so two AWG 21 wires are almost equal to one AWG 18.

\[ d = 0.127 \cdot 92^{(36-n)/39}\ \text{mm} \]

How to use it

  1. Choose the input type: Gauges (AWG) of the original wire or Section in mm².
  2. Press Accept to see the options.
  3. Under Gauges to exclude, add the ones you do not have. Exclude the original if you only want to see alternatives.
  4. Set the section tolerances above and below.
  5. Choose the wire range and press Calculate.

How to read the result

Each row gives the gauges that go together, the section they add up to in mm² and the difference from the target. The table runs from largest to smallest section. If nothing appears, widen the tolerance: consecutive gauges are quite far apart, and 1% usually leaves few options. The search only combines gauges close to each other, within 2 to 5 numbers depending on the section.

Example

An original AWG 18 (0.823 mm²) that you do not have. Exclude it and use a 5% tolerance. The clear option is 21 + 21, with 0.821 mm², just 0.25% less.

Gauge table

AWGDiameter (mm)Section (mm²)
141.6282.081
161.2911.309
181.0240.823
200.8120.518
210.7230.410
220.6440.326
230.5730.258
240.5110.205
250.4550.162
260.4050.129
280.3210.081
300.2550.051

Before you decide