Parts, excitation, armature winding and commutator
A direct-current machine converts electrical energy into mechanical energy (motor) or mechanical energy into electrical energy (dynamo or generator). The same machine can work both ways: apply a voltage and it turns; turn it and it delivers a voltage. What sets it apart from other rotating machines is the commutator, a mechanical switch that reverses the current in each rotor coil exactly when the coil passes from one pole to the next.
For decades it was the variable-speed motor par excellence: trams, trains, cranes, rolling mills, machine tools. Frequency inverters have replaced it in many applications, but it is still found in vehicle starter motors, small permanent-magnet motors, older drives that are still being repaired and, above all, in the universal motor of drills, angle grinders and vacuum cleaners, which is a commutator machine with series excitation.
Blocks of graphite or carbon-copper that slide on the commutator and carry current to the armature. They sit in brush holders with springs that keep the pressure. They are placed on the neutral axis, where the coils being commutated have no induced EMF. The contact voltage drop is about 1 V per brush, roughly 2 V in total.
As a generator: as the armature turns in the field of the poles, its conductors cut flux lines and an EMF is induced in them, with the direction given by the right-hand rule. In each conductor that voltage is alternating, because it passes alternately under N and S poles; the commutator rectifies it and a DC voltage appears at the brushes.
As a motor: when current flows through the armature conductors inside the field, a force acts on each one (left-hand rule). The commutator reverses the current in each conductor as it changes pole, so all the forces push the same way and the torque is continuous.
The two basic equations are those of the EMF and the torque:
In a motor, the applied voltage overcomes the back EMF and the internal drops:
This gives the two classic ways of controlling speed: varying the armature voltage (speeds below rated, at constant torque) or weakening the field (above rated, at constant power). The formula also warns of a danger: if the flux drops almost to zero, the speed runs away.
A 220 V motor with \(R_a = 0.5\ \Omega\) runs at 1500 rpm drawing 20 A in the armature. Its back EMF is \(E = 220 - 0.5\cdot 20 - 2 = 208\ \text{V}\). If the load rises and the current goes to 40 A with the same flux, \(E = 220 - 20 - 2 = 198\ \text{V}\) and the speed falls in the same proportion: \(1500\cdot 198/208 \approx 1428\ \text{rpm}\).
Depending on how the main-pole winding is supplied, the machine behaves very differently:
| Excitation | Field connection | Behaviour as a motor | Typical uses |
|---|---|---|---|
| Separate | Its own supply, separate from the armature | Almost constant speed; very fine control through armature voltage and field | Controlled drives, machine tools, rolling mills |
| Shunt | In parallel with the armature | Speed almost constant with load | Fans, pumps, fixed-speed machines |
| Series | In series with the armature, few turns of thick wire | Very high starting torque; speed drops sharply with load and runs away at no load | Traction, cranes, starter motors |
| Compound | One series and one shunt winding | In between: good starting torque without running away | Presses, shears, old lifts |
| Permanent magnets | No field winding | Like separate excitation with fixed flux | Small motors, automotive, toys, servos |
⚠ A series motor must never be started or run without load, and in a shunt or separately excited motor the field circuit must never be opened while the armature is energised: in both cases the flux falls and the machine can overspeed until it destroys itself.
In a compound machine, if the series field reinforces the shunt field it is called cumulative (the usual case); if it opposes it, differential. Depending on whether the shunt field is connected before or after the series field, it is called short-shunt or long-shunt.
This is the part that takes most work in the shop. The winding is closed: following the coils from bar to bar brings you back to the start. The brushes divide it into several parallel paths. It is almost always a two-layer winding: each coil has one side in the top layer of a slot and the other in the bottom layer of another slot, and the number of coils equals the number of commutator bars \(K\).
Each coil ends at the bar next to the one where it starts: \(y_c = \pm 1\) in a simplex lap winding. The winding advances under a pair of poles, goes back and overlaps like roof tiles. It has as many parallel paths as poles (\(2a = 2p\)) and needs as many brush sets as poles. It is used in high-current, moderate-voltage machines. To make the paths share current evenly, equalizer connections are added between bars that should be at the same potential.
Each coil is connected to a bar roughly one pole pair further on, so the winding travels round the rotor like a wave before returning to a bar next to the starting one. In a simplex wave winding:
It has only two parallel paths whatever the number of poles, and in theory two brushes are enough. It gives more voltage with fewer conductors: it is the winding of small and medium machines and of high-voltage ones. It needs no equalizers.
A 4-pole armature (\(p = 2\)) with 21 slots and 21 bars, simplex wave: \(y_c = (21 \pm 1)/2\), which gives 11 or 10, both whole numbers. With \(y_c = 11\) the winding is progressive; with 10, retrogressive. The coil pitch would be \(y_1 = 21/4 = 5.25 \to 5\) slots (1 to 6). With 22 bars a simplex wave winding would not be possible on 4 poles, because neither 21/2 nor 23/2 is a whole number.
Before stripping an armature for rewinding, note the number of slots and bars, the coil pitch, the commutator pitch and the position of the first coil relative to its bar (the lead offset). If this last figure is lost, the brushes will no longer sit on the neutral axis.
The armature current creates its own field, perpendicular to that of the poles. This field distorts the main flux, weakening it at one tip of each pole and strengthening it at the other, and shifts the neutral axis. This is armature reaction.
When a coil passes under a brush, its current must reverse in a very short time. Its self-inductance opposes this and, if the reversal is not complete in time, an arc jumps between brush and bar. The interpoles induce a voltage in that coil that helps reverse the current, and since they are in series with the armature their effect grows with load. Machines without them compensate by shifting the brushes slightly.
Sparking brushes point to commutation problems, brushes off the neutral axis, damaged bars, high mica, or an open or short-circuited coil.
IEC 60034-8 assigns letters to each winding. These are the ones found in the terminal box of European motors:
| Winding | Terminals |
|---|---|
| Armature | A1 – A2 |
| Interpoles | B1 – B2 |
| Compensating winding | C1 – C2 |
| Series field | D1 – D2 |
| Shunt field | E1 – E2 |
| Separately excited field | F1 – F2 |
To reverse the direction of rotation, reverse the armature current or the field current, never both at once. The usual practice is to reverse the armature together with the interpoles, so as not to disturb the residual magnetism or the compensation.
It is a series commutator motor designed to run on AC as well: when the current reverses, the field and the armature current reverse together, so the torque keeps its direction. Its stator is laminated (not solid steel) to limit losses, and it usually has two poles. It reaches very high speeds, from 10,000 to 30,000 rpm, in a small size, and its speed is easily controlled with a triac.
Its armature is almost always lap wound with many bars, and the field coils are connected on either side of the armature. Typical faults are worn brushes and commutator, armature coils burnt by stalling, and shorted turns in the field.