EN

DC machine windings

Armature with commutator and field of motors and dynamos

In development. This tool can already be used, but it is still in progress: it draws the diagram without working out turns or wire size. Nameplate data only appear in the footer. Always check the diagram before winding; you can test it in the DC armature checker.
1. What you are winding
2. Nameplate data
Optional
V
Optional. Gives the average voltage between bars
A
Optional. Gives the current per path
rpm
Optional
V
Optional
A
Optional
3. Machine
The main poles. Always even
4. Armature
If left empty, one per slot. A multiple of Z; in wave, also Z·u − 1 with a dead coil
If left empty, Z/2p rounded down
Optional. Gives the active conductors
4. Field

How to read the armature diagram

It is drawn from outside, developed, with the poles on top and the commutator below. Each slot has two lines per coil side: the left is the top layer and the right, the bottom layer. Each coil goes up the top layer of one slot, through the head above and down the bottom layer y1 slots further on. Its two ends go to two bars, yc apart.

Each colour is a path, from one brush to the other. In grey, the coils the brushes are short-circuiting at this instant: they are commutating. The arrow at the top is where the armature moves in the drawing: to the right is clockwise seen from the commutator.

Lap or wave

LapWave
Commutator pitch yc±m(K ± m) / p, whole
Parallel paths (2a)2p·m2m
BrushesOne per pole2 would do; usually one per pole
EqualizersYes, from 4 polesNot needed
Where it is usedHigh current and moderate voltage; universal motorsSmall and medium machines; more voltage with fewer conductors

Here m is the plex: 1 in simplex and 2 in duplex, and p is the pole pairs. With 21 bars and 4 poles, a simplex wave allows yc = 10 or yc = 11. With 22 bars there is no simplex wave.

Coils per slot and dead coil

Each bar corresponds to one coil, so with K = 2·Z there are two coils per slot, side by side, and they should be kept clearly in their layers. When a wave winding narrowly fails to work out, the armature is fitted as normal and one dead coil is left: it takes its place to keep the balance, but with its ends insulated. For example, 22 slots and 21 bars at 4 poles.

Progressive or retrogressive

This is which way the path moves from bar to bar. Progressive lap and retrogressive wave do not cross the connections: they are the usual ones and what the default option gives. The other two cross them and give the opposite rotation with the same supply: when copying an armature, keep what it had.

Where the brushes go

The diagram makes each coil's connections symmetrical about its axis. That is why the brushes come out under the centre of the poles, where the coil they commutate is in the neutral line. If the original armature had offset connections, the brushes are offset too. Before stripping, note which bars the coil in slot 1 goes to.

Equalizer connections

In a lap winding of 4 poles or more, the poles are never quite identical and the paths do not give exactly the same. Those differences would drive current through the brushes. Equalizers join bars that should be at the same voltage, K/p bars apart, so that the current shares out that way. The message lists them; they are not drawn so that the diagram stays readable.

The field and the interpoles

The pole coils are connected so that N and S alternate, and here they are drawn seen from inside. Interpoles go in series with the armature, because their effect has to grow with the load. In a motor they have the polarity of the main pole the conductor has just left and in a generator, of the one it is heading for. Fitted the wrong way round, it sparks far more than without them.

Before fitting

More explanation in the guide DC machine fundamentals. For speed, torque and starting, DC motor analysis.