Enamelled copper wire table for motor, transformer and coil windings: metric diameters (IEC) and American gauges (AWG) from 0.05 mm to 11.86 mm, with cross-section, weight per kilometre, approximate current rating and electrical resistance.

Show:
Enamelled copper wire. Values at 20 °C; current is approximate.
IECØ nominal AWGgauge Ømm Sectionmm² Weightkg/km CurrentA ResistanceΩ/km
440.05030.0019870.018020.0056238500
430.056410.0024990.022660.0070716759
420.063340.0031510.028570.0089175360
410.071130.0039730.036020.011244251
400.079870.005010.045420.014183371
390.089690.0063180.057280.017882673
0.10.10.0078540.071210.022232151
380.10070.0079670.072230.022542120
0.110.110.0095030.086160.026891777
370.11310.010050.091080.028431681
0.120.120.011310.10250.0321493
360.1270.012670.11480.035851333
0.130.130.013270.12030.037561273
0.140.140.015390.13960.043561097
350.14260.015970.14480.04521057
0.150.150.017670.16020.05001955.8
0.160.160.020110.18230.0569840.1
340.16010.020140.18260.057838.6
0.170.170.02270.20580.06423744.1
330.17980.02540.23030.07188665
0.180.180.025450.23070.07201663.8
0.190.190.028350.25710.08023595.7
0.20.20.031420.28480.0889537.6
320.20190.032030.29040.09063527.4
0.210.210.034640.3140.09801487.7
0.220.220.038010.34460.1076444.3
310.22680.040390.36610.1143418.2
0.230.230.041550.37670.1176406.5
0.240.240.045240.41010.128373.4
0.250.250.049090.4450.1389344.1
300.25460.050930.46170.1441331.7
290.28590.064220.58220.1817263
0.30.30.070690.64090.2239
280.32110.080980.73410.2291208.6
0.350.350.096210.87230.2723175.6
270.36060.10210.92570.289165.4
0.40.40.12571.1390.3556134.4
260.40490.12881.1670.3644131.2
0.450.450.1591.4420.4501106.2
250.45470.16241.4720.4595104
0.50.50.19631.780.555686.02
240.51060.20471.8560.579482.5
0.550.550.23762.1540.672371.09
230.57330.25822.3410.730665.43
0.60.60.28272.5630.800159.74
220.64380.32552.9510.921251.89
0.650.650.33183.0080.93950.9
0.70.70.38483.4891.08943.89
210.72290.41053.7221.16241.15
0.750.750.44184.0051.2538.23
0.80.80.50274.5571.42233.6
200.81180.51764.6931.46532.63
0.850.850.56755.1451.60629.77
0.90.90.63625.7681.826.55
190.91160.65275.9181.84725.88
0.950.950.70886.4262.00623.83
110.78547.1212.22321.51
181.0240.8237.4622.32920.52
1.051.050.86597.852.4519.51
1.11.10.95038.6162.68917.77
171.151.0389.4092.93716.27
1.151.151.0399.4172.93916.26
1.21.21.13110.253.214.93
1.251.251.22711.133.47313.76
161.2911.30911.863.70312.91
1.31.31.32712.033.75612.73
1.351.351.43112.984.05111.8
1.41.41.53913.964.35610.97
151.451.6514.964.6710.24
1.451.451.65114.974.67310.23
1.51.51.76716.025.0019.558
1.551.551.88717.115.348.951
1.61.62.01118.235.698.401
141.6282.08118.875.8898.117
1.651.652.13819.396.0517.899
1.71.72.2720.586.4237.441
1.751.752.40521.816.8077.022
1.81.82.54523.077.2016.638
131.8282.62423.797.4256.437
1.851.852.68824.377.6076.284
1.91.92.83525.718.0235.957
1.951.952.98627.088.4515.656
223.14228.488.895.376
122.0533.309309.3635.105
2.12.13.46431.49.8014.877
2.22.23.80134.4610.764.443
2.32.34.15537.6711.764.065
112.3054.17237.8311.814.048
2.42.44.52441.0112.83.734
2.52.54.90944.513.893.441
102.5885.26147.714.893.21
2.62.65.30948.1415.023.181
2.72.75.72651.9116.22.95
2.82.86.15855.8317.422.743
2.92.96.60559.8818.692.557
92.9066.63460.1518.772.546
337.06964.09202.39
83.2648.36675.8423.672.019
3.53.59.62187.2327.231.756
73.66510.5595.6429.851.601
4412.57113.935.561.344
64.11513.3120.637.641.27
4.54.515.9144.245.011.062
54.62116.77152.147.471.007
5519.6317855.560.8602
45.18921.15191.859.850.7986
5.55.523.76215.467.230.7109
35.82726.67241.875.470.6333
6628.27256.380.010.5974
6.56.533.18300.893.90.509
26.54433.63304.995.170.5022
7738.48348.9108.90.4389
17.34842.41384.51200.3983
7.57.544.18400.51250.3823
8850.27455.7142.20.336
08.25253.48484.9151.30.3158
8.58.556.75514.5160.60.2977
9963.62576.81800.2655
009.22666.85606.1189.20.2527
101078.54712.1222.30.2151
00010.484.95770.2240.40.1988
000011.86110.51002312.60.1529

How to read the table

ColumnMeaning
IECNominal copper diameter in millimetres according to the metric series, the most widely used in Europe.
AWGAmerican Wire Gauge, the US wire size system. The higher the number, the thinner the wire.
Ø mmDiameter of the copper conductor, excluding the enamel.
SectionConductor area in mm². It determines the resistance and the current the wire can carry.
WeightKilograms per kilometre of wire. Useful for estimating how much wire to buy for a winding.
CurrentApproximate current at a density of about 2.83 A/mm², a conservative value.
ResistanceElectrical resistance in ohms per kilometre at 20 °C.

Useful formulas

Cross-section from diameter:

S (mm²) = π · d² / 4

Resistance of a winding of length L (in metres):

R (Ω) = Rkm · L / 1000

Resistance correction for temperature (copper):

RT = R20 · [1 + 0.00393 · (T − 20)]

AWG diameter from gauge number n:

d (mm) = 0.127 · 92(36 − n) / 39

Equivalent diameter when one wire is replaced by N wires in parallel:

dN = d / √N

Worked example

When rewinding a motor you find 1 mm wire, but it is out of stock. Two wires of 1 / √2 ≈ 0.71 mm can be used in parallel; with 0.7 mm wire the total cross-section is 2 · 0.3848 = 0.77 mm², practically the same as 1 mm (0.7854 mm²). If the winding uses 120 m of 1 mm wire, its resistance at 20 °C will be 21.51 · 120 / 1000 ≈ 2.58 Ω and it will weigh about 7.121 · 0.12 ≈ 0.85 kg.

Current density in windings

The current column uses a low density so that it can serve as a safe reference. In practice, the allowable current density depends on cooling, insulation class and duty type: well-ventilated machines work at considerably higher densities than an enclosed transformer or an unventilated coil. To size a winding, use the data of the original winding or the manufacturer as a reference.

Approximate values. Actual diameters including enamel are somewhat larger and depend on the insulation grade (grade 1, 2 or 3); check the wire manufacturer's data sheet.