EN

DC armature checker

Paths, commutation and bar-to-bar test, with the circuit solved coil by coil

Enter the slots, bars, poles and pitches, or import a diagram from DC machine windings. You start with a wave winding of 21 slots and 4 poles.

The poles and brushes are fixed; the rotor and commutator move. Red: current goes up the left side of the coil. Blue: down. Grey: almost no current. In black, the watched coil. Click a pole to swap N and S.
Simulation
Electrical degrees off the neutral line
Armature current, relative to rated
Parallel paths
Brushes
Voltage between brushes
Ripple
Current per path
Voltage in the commutating coil
No-load voltage while moving one pole pair, relative to a healthy armature with the brushes in place (dashed).
Current in the watched coil. It reverses under the brush: that is commutating.
Armature
Negative: retrogressive in a lap
Interpoles
Click one to swap n and s
Faults and bar-to-bar test
Reading between each bar and the next, with 1 A and no brushes. In orange, those that stand out from the rest of their section.

What it is for

A DC armature is not tested like a stator: it is a closed circuit that the brushes split into paths, and those paths change coils at every instant. This checker builds that circuit from the data you enter and solves it at each rotor position. It takes no winding type for granted: if a pitch is wrong, you see it.

How to use it

  1. Enter Z, K, poles, y1 and yc, load an example or import a diagram.
  2. Read the diagnosis: which winding it is, how many paths it gives and whether they are equal.
  3. Press Animate or advance little by little, and watch a coil pass from one path to another under the brush.
  4. Move the brush shift, or choose a fault, and see what changes.

What it checks

How to read the bar-to-bar test

This is the workshop test: direct current goes in through two bars and you measure between each two consecutive ones. In a lap winding there are two heights, one per current route. In a wave winding, there are p coils in series between two consecutive bars. What matters is the bar that stands out: very high for an open coil, very low for a shorted one. If the current does not enter at bars one pole pitch apart, the heights change, but the odd bar stays in the same place.

A coil with both ends swapped does not show in this test, because the resistance is the same. It shows when the connections of two coils are crossed, and with the machine running: voltage falls and current circulates.

Limits of the simulation. It is a circuit of resistances with induced voltages, a trapezoidal field with a 70 % pole arc and brushes with uniform contact. Commutation is resistive: it does not see the coil's self-inductance, armature reaction or saturation, so interpoles are only checked for polarity. The values are relative, not those of your machine. It serves to test the winding and understand what happens, not to design a real motor.