Why a motor turns: the force on a conductor, the commutator and the back EMF
A current-carrying conductor in a magnetic field feels a force perpendicular to both the field and the current. If the conductor is part of a loop that can turn, that force produces torque: it is the principle of every electric motor. And as it turns, the loop cuts the field and generates a voltage that opposes the supply.
The force on a conductor
\[ F = B\,I\,L\,\sin\theta \]
B is the flux density in teslas, I the current, L the length of conductor inside the field and θ the angle between conductor and field. With the conductor perpendicular to the field, F = B·I·L.
The direction is given by the left-hand rule: field with the index finger, current with the middle finger and force with the thumb.
Example: 0.8 T, 10 A and 20 cm of conductor give 1.6 N. A rotor with hundreds of conductors in that situation adds up to considerable torque.
On a free moving charge, the force is \( F = q\,v\,B \). It is the force that deflects the electrons in a Hall-effect sensor, which DC clamp meters use to measure current.
Simulator: the elementary motor
· current coming out, × going in; the blue arrows are the forces. The graph shows the torque versus angle for the chosen rotor. Coil resistance 4 Ω and N·B·A = 0.5 V·s. The animation runs in slow motion; the rpm are real.
Things to try
Without a commutator, the loop turns a little, overshoots the vertical and comes back: the torque reverses every half turn and it ends up stopped. A DC motor needs to reverse the current exactly there.
With a commutator, the current reverses every half turn and the torque always pushes the same way. But with a single loop there are two dead points: raise the load torque and you will see that, once stopped at one of them, it no longer starts.
With two coils or many, the torque hardly drops at any angle. That is why armatures have many coils and many segments.
The starting current is the voltage divided by the resistance: 3 A at 12 V. As it speeds up, the back EMF rises and the current falls.
Raise the load torque: the speed drops, the back EMF drops and the current rises until it gives the torque the load demands.
Back EMF
The turning loop is also a generator: it cuts the field and a voltage E is induced in it that opposes the supply. It is what you see on the induction page, but inside the motor itself:
\[ I = \frac{U - E}{R} \qquad E = k\,\Phi\,n \qquad M = k'\,\Phi\,I \]
Starting: at standstill, E = 0 and the current is limited only by the winding resistance, which is small. That is why large DC motors start with series resistors or a drive.
Running: the speed rises until E approaches U. The current settles at just what is needed for the load torque and the losses.
Locked rotor: if the load prevents rotation, the current stays at the starting value and the winding burns out.
Weakening the field of a separately excited motor means it needs more speed to produce the same E: the motor speeds up. If the excitation is lost at light load, it runs away.