Check a three-phase winding: arrows per slot, N and S poles, and direct or reverse sequence
Draw an arrow in each slot, or import a diagram from Three-phase windings, and animate the currents to see whether the field rotates as it should. You start with an example of 24 slots and 4 poles.
In a properly made three-phase winding, the three currents together create a magnetic field that rotates at constant speed. This tool shows it on the developed diagram: each slot is a vertical line and each arrow is the direction of the current in that conductor. Use it to check a diagram before winding, to understand the rotating field, and to see what happens when a phase is connected backwards.
The arrows you draw are a snapshot of one instant, just like a winding diagram. The three currents add up to zero, so they can never all be positive at once: at every instant, one runs the opposite way from the other two. The tool respects your drawing: it recognises which phase is reversed and starts with it at −1 and the other two at +0.5, so every arrow keeps the direction you gave it.
For example, with 24 slots and 4 poles and W reversed, two at a time: U up, V down, W down, U down, V up, W up, and repeat. That leaves six arrows in a row pointing one way and six pointing the other, and each group corresponds to one pole.
If it goes wrong: if no phase is reversed or some arrow is the wrong way round, the field comes out irregular: N and S jerk along and their strength rises and falls. The diagnosis below the drawing tells you which phase to correct: turn all its arrows round and try again. If no whole phase fixes it, individual arrows are wrong: go through the drawing slot by slot.
In Three-phase windings, calculate a diagram and press Check: direct sequence or Check: reverse sequence. It opens here with all the slots filled in and at the instant of the diagram, so the arrows match the ones you see there. When animated, a correct diagram must give a uniform field.
If you then press Back to drawing, you will see the same arrows as in the diagram.
This is a typical fault when wiring the terminal board: the start and end of a phase get swapped (U with X, V with Y or W with Z). It happens above all after rewinding, when the leads are not properly identified. For the motor it is the same as reversing all the arrows of that phase, and the board looks correct at a glance, so it is not discovered until tested. On this site the terminals are called U-X, V-Y and W-Z; on many current boards they are U1-U2, V1-V2 and W1-W2.
You can see it with the example: animate it and press Reverse W. The field stops being uniform and the poles jerk along. In this case they even move backwards, because the wave rotating the wrong way is twice the one rotating the intended way, and its strength swings between one third and the maximum. Reversing two phases is equivalent to reversing the third with N and S swapped; reversing all three does not change the rotation.
| What is wrong | What you see here | What usually happens in the motor |
|---|---|---|
| Nothing | N and S advance at a constant rate. | It starts and runs well, with similar currents in the three phases. |
| One phase reversed, in star | Jerky poles and varying strength. | Humming and vibration, little torque, difficult or no starting, high and unequal currents. It heats up quickly. |
| One phase reversed, in delta | Jerky poles and varying strength. | More serious: inside the delta the three voltages no longer add up to zero but to twice the phase voltage. A very high current flows even at no load: disconnect it immediately. |
| A coil group reversed within a phase | Irregular field (draw it by hand to see it). | Less torque, noise, unequal currents and heating. |
| Two supply phases swapped (reverse sequence) | Uniform field going the other way. | Not a fault: it works well but rotates backwards. Fix it by swapping two supply phases. |
For the links on the board, see star and delta connection and dual-voltage motors.
If the leads are unmarked, follow the guide to identifying the 6 leads.