EN

Rotating field

Check a three-phase winding: arrows per slot, N and S poles, and direct or reverse sequence

Draw an arrow in each slot, or import a diagram from Three-phase windings, and animate the currents to see whether the field rotates as it should. You start with an example of 24 slots and 4 poles.

Before you draw: draw one of the three phases reversed, whichever you like. The three currents add up to zero, so at every instant one runs the opposite way from the other two. The tool takes your arrows exactly as you draw them and starts the simulation at that instant.

Simulation
Current U
Current V
Current W
Drawing the arrows
Arrow of phase
Colours
Connection fault

Swaps the start and end of a phase, as if they were wrongly connected on the terminal board. Press again to undo.

What it is for

In a properly made three-phase winding, the three currents together create a magnetic field that rotates at constant speed. This tool shows it on the developed diagram: each slot is a vertical line and each arrow is the direction of the current in that conductor. Use it to check a diagram before winding, to understand the rotating field, and to see what happens when a phase is connected backwards.

How to use it

  1. Enter the number of stator slots (Z).
  2. Choose the phase and click each slot: in the upper half the arrow points up, in the lower half it points down. Erase or a right click removes it. With a mouse you can drag; on a phone, swipe the drawing sideways if it does not fit.
  3. Choose the sequence: direct (U → V → W) or reverse (U → W → V).
  4. Press Animate, advance with Step +30° or move the angle. Each arrow grows, shrinks to 0 and flips according to the current in its phase.
  5. Watch N and S and read the diagnosis below the drawing: it says whether the field is uniform, irregular or pulsating, and which way it moves.

Why one phase must be drawn reversed

The arrows you draw are a snapshot of one instant, just like a winding diagram. The three currents add up to zero, so they can never all be positive at once: at every instant, one runs the opposite way from the other two. The tool respects your drawing: it recognises which phase is reversed and starts with it at −1 and the other two at +0.5, so every arrow keeps the direction you gave it.

For example, with 24 slots and 4 poles and W reversed, two at a time: U up, V down, W down, U down, V up, W up, and repeat. That leaves six arrows in a row pointing one way and six pointing the other, and each group corresponds to one pole.

If it goes wrong: if no phase is reversed or some arrow is the wrong way round, the field comes out irregular: N and S jerk along and their strength rises and falls. The diagnosis below the drawing tells you which phase to correct: turn all its arrows round and try again. If no whole phase fixes it, individual arrows are wrong: go through the drawing slot by slot.

Importing a result from Three-phase windings

In Three-phase windings, calculate a diagram and press Check: direct sequence or Check: reverse sequence. It opens here with all the slots filled in and at the instant of the diagram, so the arrows match the ones you see there. When animated, a correct diagram must give a uniform field.

If you then press Back to drawing, you will see the same arrows as in the diagram.

What you are seeing

What happens if the arrows are wrong

This is a typical fault when wiring the terminal board: the start and end of a phase get swapped (U with X, V with Y or W with Z). It happens above all after rewinding, when the leads are not properly identified. For the motor it is the same as reversing all the arrows of that phase, and the board looks correct at a glance, so it is not discovered until tested. On this site the terminals are called U-X, V-Y and W-Z; on many current boards they are U1-U2, V1-V2 and W1-W2.

You can see it with the example: animate it and press Reverse W. The field stops being uniform and the poles jerk along. In this case they even move backwards, because the wave rotating the wrong way is twice the one rotating the intended way, and its strength swings between one third and the maximum. Reversing two phases is equivalent to reversing the third with N and S swapped; reversing all three does not change the rotation.

What is wrongWhat you see hereWhat usually happens in the motor
NothingN and S advance at a constant rate.It starts and runs well, with similar currents in the three phases.
One phase reversed, in starJerky poles and varying strength.Humming and vibration, little torque, difficult or no starting, high and unequal currents. It heats up quickly.
One phase reversed, in deltaJerky poles and varying strength.More serious: inside the delta the three voltages no longer add up to zero but to twice the phase voltage. A very high current flows even at no load: disconnect it immediately.
A coil group reversed within a phaseIrregular field (draw it by hand to see it).Less torque, noise, unequal currents and heating.
Two supply phases swapped (reverse sequence)Uniform field going the other way.Not a fault: it works well but rotates backwards. Fix it by swapping two supply phases.
Limits of the simulation. It is an ideal model: it imposes three equal sinusoidal currents and only considers how they are distributed in the slots, with one arrow per slot, so double-layer windings cannot be represented yet. It does not model the motor: in reality, with a reversed phase the currents become unbalanced too. The last column of the table lists usual effects, not a calculation of your case.

How to avoid it

For the links on the board, see star and delta connection and dual-voltage motors.

If the leads are unmarked, follow the guide to identifying the 6 leads.