Faraday's law, Lenz's law, the elementary generator and eddy currents
When the magnetic flux through a coil changes, a voltage appears in the coil. It does not matter why it changes: because a magnet moves, because the coil turns or because the current in a nearby coil varies. Generators, transformers, clamp meters and inductive sensors are all based on this.
Faraday's law and Lenz's law
\[ e = -N\,\frac{d\Phi}{dt} \]
Faraday: the voltage is proportional to the number of turns and to how fast the flux changes. A large but steady flux induces nothing.
Lenz: the minus sign says that the induced current creates a flux that opposes the change. If the magnet approaches, the coil repels it; if it moves away, the coil attracts it. That is why it is hard to move a magnet near a short-circuited coil, and why a generator brakes when you draw current from it.
Simulator: magnet and coil
Drag the magnet with your finger or the mouse. The letter next to the coil is the pole created by the induced current on the face looking at the magnet.
Things to try
Bring the magnet in slowly, then quickly: the needle moves more the faster it goes. Standing still, even inside the coil, it reads nothing.
Moving in and moving out, the needle swings to opposite sides.
Turn the magnet round: everything changes sign.
Double the turns: the voltage doubles.
The elementary generator
A loop turning between two poles sees a flux that changes all the time. The voltage is greatest when the conductors cut the field lines head-on and zero when they move parallel to them, in the so-called neutral zone:
\[ e = N\,B\,A\,\omega\,\sin(\omega t) \qquad E_{rms} = \frac{N B A \omega}{\sqrt{2}} \]
The animation turns slowly so you can follow it; the values are calculated at the chosen speed. With two poles, 3000 rpm gives 50 Hz.
With slip rings each end of the loop always goes to the same terminal and the output is AC. That is how alternators work.
With a commutator the terminals swap exactly in the neutral zone and the voltage always has the same sign. With one loop it pulses strongly; with many distributed coils the ripples overlap and the output is nearly smooth DC. That is the dynamo, and that is why the brushes must sit in the neutral zone. See DC machine fundamentals.
The right-hand rule gives the direction of the current induced in a conductor moving in a field.
In the transformer
Here nothing moves: the flux changes because the current is alternating. With a sinusoidal flux of peak value Φmax = Bmax·A, the RMS voltage of each winding is:
\[ E = 4.44\, f\, N\, B_{max}\, A \]
Both coils see the same flux, so the volts per turn are the same in both: the voltage ratio is the turns ratio. The same formula sets how many turns a motor or transformer needs so as not to saturate the iron; it is explained in the magnetic circuit page.
Example
A transformer with a 10 cm² core at 1.2 T and 50 Hz gives \( 4.44 \cdot 50 \cdot 1.2 \cdot 0.001 = 0.266 \) V per turn. 230 V needs 230 / 0.266 ≈ 865 turns, and 24 V about 90.
Eddy currents
Iron is a conductor too. If the flux through it changes, currents are induced inside the iron itself, circulating in whirls and heating it. These are eddy (Foucault) currents. To limit them, AC cores are built from thin sheets insulated from each other: each whirl is trapped inside a narrow sheet.
\[ P \approx \frac{\pi^2\, d^2\, f^2\, B_{max}^2}{6\,\rho} \quad (\text{W/m}^3) \]
Losses grow with the square of the sheet thickness d, of the frequency and of the flux density. The silicon in electrical steel raises its resistivity ρ and reduces them further.
Eddy-current losses only, with the classical formula. Total core losses are higher: hysteresis and excess losses must be added. The values are for comparing thicknesses.
Going from 0.5 to 0.35 mm halves the eddy-current losses. That is why good transformers use 0.23 to 0.30 mm steel.
A 50 Hz motor fed from a drive at 100 Hz quadruples these losses at the same flux density. Thinner steel or ferrite is used for high frequencies.
The skin depth δ shows how far the field penetrates. If the sheet is thicker than δ, the flux crowds at the surface and the formula no longer holds, but the losses are still very high.
When rewinding, stators must not be burnt off at excessive temperature to remove varnish: the interlaminar insulation is damaged, the whirls pass from sheet to sheet and the rewound motor runs hotter than before.
Where induction is put to use
Clamp meter: the cable is the primary turn and the clamp a transformer. That is why ordinary clamps cannot measure DC; those that can use a Hall sensor.
Inductive sensors: they create an alternating field and detect the eddy currents in an approaching metal. See their wiring in sensors in series and parallel.
Induction hobs and furnaces: they heat on purpose with eddy currents, at 20 to 100 kHz.
Eddy-current brakes: a disc turning between magnets is braked without friction, as in trains and test benches.
Induced voltages in cables: a disconnected cable running alongside others carrying current can have a dangerous induced voltage. Earth it before working on it.