Motor power from its dimensions

How many kW an induction motor can deliver given its rotor diameter, core length and speed

When a motor arrives without a nameplate, or an empty stator is to be rewound for another speed, the first question is how much power it can deliver. The answer lies in the size of the rotor: power grows with the volume D²·L and with speed, and the rest is set by what the motor withstands without overheating. The calculator gives an indicative range with typical values for industrial motors, and below it explains where it comes from.

Calculator

Rotor
mm
mm
Motor
rpm

Range with the low and high values of B and A typical for that diameter and number of poles; the central value uses the mean ones. Continuous duty S1, class F insulation with class B temperature rise and winding factor 0.95. It is an estimate to get your bearings: a manufacturer can get noticeably more out of the same laminations with better cooling or materials, and an old or cheap motor, less.

L D
D is the outer diameter of the rotor (almost the same as the stator bore) and L the length of the lamination stack, without end windings or fan.

Esson’s output equation

The power a motor converts depends on two things that can be measured on the laminations: the magnetic field crossing the air gap and the current carried by the slot conductors. Multiplied by the air-gap surface and by the speed, they give the apparent power:

\[ S = 11 \cdot K_w \cdot B \cdot A \cdot D^2 \cdot L \cdot n_s \cdot 10^{-3} \quad (\text{kVA}) \]

The number 11 is \(\pi^2/\sqrt{2}\) rounded. The output power at the shaft is \(P = S \cdot \eta \cdot \cos\varphi\): in small motors the product \(\eta \cdot \cos\varphi\) is around 0.6, and in motors of tens of kW it reaches 0.8.

Magnetic loading and electric loading

B and A do not come from the geometry: they are what the iron and the copper can withstand. B is limited by saturation of the teeth and the yoke, and A by the heat the current produces in the copper and by how well that heat is removed. These are the typical values the calculator uses:

Rotor diameterA (kA/m), enclosed with fan
50 mm11 to 19
90 mm24 to 36
200 mm29 to 42
350 mm35 to 50
600 mm or more40 to 60
PolesMean B (T)Why
20.40 to 0.50All the flux of a pole goes through the yoke, which is what saturates
40.42 to 0.52The most balanced case
6 or more0.45 to 0.55The yoke has room to spare and the tooth sets the limit

Mean B is \(2/\pi\) of the peak: a mean B of 0.47 T is about 0.74 T (7400 G) peak in the air gap. A grows with size because a large motor has more slot depth for each metre of circumference. With an open motor or a separate fan, A can be raised by 15 or 20 %; without a fan, it must be lowered to two thirds.

Example

A rotor 100 mm in diameter with a 100 mm stack, from a 1450 rpm motor at 50 Hz (4 poles, \(n_s\) = 25 revolutions per second), with the mean values B = 0.47 T and A = 31 kA/m:

\[ S = 11 \cdot 0.95 \cdot 0.47 \cdot 31\,000 \cdot 0.1^2 \cdot 0.1 \cdot 25 \cdot 10^{-3} \approx 3.8 \text{ kVA} \]

With \(\eta \cdot \cos\varphi \approx 0.65\) this gives about 2.5 kW, and with the low and high values, 1.7 to 3.4 kW. A 90L or 100L frame motor of 1.5 to 3 kW has a rotor of that size, so the result checks out.

What really limits power: heat

The formula does not say how much power the motor can deliver, but how much it converts with given B and A. The real limit is temperature: copper losses grow with the square of the current and the insulation has a maximum (155 °C for class F). That is why:

Speed and poles

With the same rotor, power is almost proportional to speed: at 3000 rpm it gives nearly twice as much as at 1500 rpm, and at 750 rpm, half. Torque, on the other hand, depends mainly on the volume \(D^2 \cdot L\) and hardly changes with the poles. That is why a slow motor is much larger than a fast one of the same power. With 2 poles B has to be somewhat lower and the gain does not reach double. To change the poles of an existing motor, see the guide on modifying the winding.

Motor shape: long in 2 poles, squat in 8

Line up motors of the same power and the 2-pole ones have a narrow, long rotor, while the 6- or 8-pole ones have a wide, short one. The same volume \(D^2 \cdot L\) fits many shapes, but each pole number has its own for magnetic and mechanical reasons. The quantity that sorts it out is the pole pitch, the arc of rotor taken up by each pole:

\[ \tau_p = \frac{\pi \cdot D}{2p} \]

where 2p is the number of poles. With D = 100 mm, one pole of a 2-pole motor spans 157 mm of arc; one of an 8-pole motor, only 39 mm.

Magnetic constraints

Mechanical constraints

The extreme cases are alternators: 2-pole turbo-generators have rotors about one metre across and several metres long, while those in hydro plants, with dozens of poles, are discs several metres across with a short core. For catalogue motors, these are typical proportions:

PolesStator bore / lamination outer diameterUsual L/D
20.52 to 0.601 to 2
40.62 to 0.680.8 to 1.3
60.68 to 0.720.6 to 1
8 or more0.70 to 0.750.5 to 0.9

You notice it when changing the poles of an existing motor. A long 2-pole stator rewound for 8 poles has yoke to spare but little diameter: power drops more than in proportion to speed and the no-load current is high. The other way round, a squat 6- or 8-pole stator rewound for 2 poles has a yoke sized for its old flux, which would now be three or four times larger: the flux density has to come down a lot and power barely rises. Before going to fewer poles, measure the yoke depth and compare it with the formula above. The calculator does not look at the shape, only the volume: if your rotor is very different from the usual for its poles, stay at the low end of the range.

How to measure the rotor

Frequently asked questions

Is this the maximum power of the motor?

It is the power it can deliver continuously without exceeding its temperature, the nameplate power. For a few seconds an induction motor gives 2 or 3 times its rated torque (the maximum or breakdown torque), but it cannot sustain it for long.

Does it work for permanent magnet or DC motors?

The equation is the same for all rotating machines, but the values of B and A change: permanent magnet motors work with higher B and DC machines have their own table. The calculator uses values for squirrel-cage induction motors.

Why do I get less power than my motor’s nameplate?

Modern high-efficiency motors (IE3, IE4) and those from manufacturers who push the design reach or exceed the high values of A, and some motors have a longer stack than it seems from outside. If the nameplate gives more than the high value, the motor is already pushed and it is better not to raise its power when rewinding.

What if I want the turns and the wire?

With the power and the voltage, the turns from the stator calculator gives the turns per phase and the wire section from the lamination measurements.

Related: turns from the stator, modifying the winding of an induction motor, induction motor fundamentals and induction motor analysis.