Equivalent circuit, power balance, torque and efficiency, torque-speed curve and tests
An induction motor behaves like a transformer whose secondary (the rotor) rotates. With everything referred to the stator, each phase is represented by the circuit below. The parameters are those of the equivalent star: if the motor is delta-connected, the phase impedances are divided by 3.
\(p\) is the number of pole pairs and \(s\) the slip: 0 at synchronous speed, 1 with the rotor at standstill, normally between 1 % and 6 % at full load.
The power crossing the air gap, \(P_a\), is always split in the same proportion: a fraction \(s\) is lost in the rotor copper and the rest is converted into mechanical power. That is why a motor with a lot of slip can never have a good efficiency. The electromagnetic torque is \(T = P_a / \Omega_s\) and the output torque \(T_u = P_u / \Omega\).
Replacing the supply with its Thévenin equivalent as seen from the rotor (\(V_{th}\), \(R_{th} + jX_{th}\)):
The circuit parameters are obtained from three simple measurements on the test bench:
How \(X_{cc}\) is split between stator and rotor depends on the cage design (NEMA classification):
| Design | \(X_1\) | \(X_2'\) | Characteristics |
|---|---|---|---|
| A and D, wound rotor | 50 % | 50 % | Normal starting torque (A) or very high with large slip (D) |
| B | 40 % | 60 % | The general-purpose motor |
| C | 30 % | 70 % | Double cage: high starting torque |
Mechanical losses can only be separated from iron losses by repeating the no-load test at several voltages; if they are unknown, they are typically around 1 % to 2 % of rated power in medium-sized motors.
With the calculator's default parameters and a slip of 3 %: \(n_s = 1500\) rpm and \(n = 1455\) rpm.
The calculator completes the balance: about 8.6 kW output, 56.6 N·m and an efficiency close to 88 %. The breakdown torque, about 164 N·m, is reached at around 1220 rpm.