Speed, torque, starting, speed control and efficiency with separate, shunt or series excitation
As it rotates in the field of the poles, the armature generates a back EMF \(E\) proportional to the flux and the speed; the armature current, in that same field, produces a torque proportional to the flux and the current. With the machine constant grouped as \(k\Phi\) (in V·s/rad, which is the same as N·m/A):
Solving for the speed gives the equation that governs the whole behaviour of the motor:
| Excitation | Flux | Torque-speed curve | Typical use |
|---|---|---|---|
| Separate | Constant, from a separate source | Almost horizontal line: speed drops little with load | Drives controlled by armature voltage |
| Shunt | Constant if the voltage is | Same as separate excitation | Machine tools, fans |
| Series | Proportional to the current | Hyperbola: high torque at low speed; runs away at no load | Traction, cranes, universal motors |
| Compound | Sum of both | Intermediate | Loads with torque shocks |
In the series motor the flux grows with the current, so torque grows with its square (\(T \propto I^2\)) as long as the magnetic circuit does not saturate. Without load the current is small, so is the flux, and the speed rises without limit: a series motor must never be started or run without load, nor coupled with belts that could slip off.
At standstill \(E = 0\) and the only limit on the current is the armature resistance, which is very small. To keep the current drawn at start below \(k\) times rated current, a rheostat is inserted:
In the series motor the resistance of the field winding, which is in the same circuit, is added as well.
The rheostat is cut out in steps as the motor accelerates and the back EMF builds up.
\(P_{rot}\) groups the mechanical and iron losses. The calculator derives them from the nameplate data (the difference between rated internal power and output power) and treats them as a constant loss torque.
Ra = 0.25 Ω, Rexc = 110 Ω and a 2 V brush drop.
With direct-on-line starting \((220 - 2)/0.25 = 872\) A would flow, almost 17 times rated current. To keep the current drawn below 2·In = 104 A, the armature may take 102 A (the other 2 A are for the field), which calls for a rheostat of \(218/102 - 0.25 = 1.89\ \Omega\).
Related: DC machine fundamentals · H-bridge for DC motors · induction motor analysis