EN

Single-phase field checker

Main and auxiliary: axes at 90°, circular, elliptical or pulsating field, and which way it rotates

Draw the arrows of the main and auxiliary windings, or import a diagram from Single-phase windings, and see what field you get. You start with an example of 24 slots and 4 poles.

Before drawing: nothing needs to be inverted here. Draw each conductor with the direction of its positive current. The phase shift between main and auxiliary decides the rotation.

Simulation
Sets an approximate phase shift and strength
Relative to the main winding
Centrifugal switch
Main current
Auxiliary current
Curve the field follows in one cycle. Dashes: the axis of each winding, red for main and blue for auxiliary. If it moves anticlockwise, the field is heading towards higher-numbered slots.
Drawing the arrows
Arrow of the winding
Direction of rotation

Swaps the two ends of the auxiliary, as in the terminal box. This is what reverses the rotation. Press again to undo it.

What it is for

A single winding with alternating current gives a pulsating field that does not rotate, which is why a single-phase motor does not start by itself. The auxiliary, 90 electrical degrees away and with its current shifted, makes the field rotate. This tool checks both things separately: that the winding is drawn correctly and what field it gives with the phase shift of each motor type.

How to use it

  1. Enter the slots (Z) and choose the winding.
  2. Press each slot: in the top half the arrow goes up and in the bottom half it goes down. Delete or a right click removes it. With a mouse you can drag.
  3. Choose the motor type or move the phase shift and strength.
  4. Press Animate, advance with Step +30° or move the angle, and read the diagnosis under the drawing.

What it checks

How to read the field

FieldCurveWhat it means
CircularCircleAxes at 90°, currents at 90° and equal strength. The best case: constant torque and no vibration from the field.
EllipticalEllipseIt rotates, but with varying strength. This is normal in a real motor: the narrower the ellipse, the lower the starting torque and the more vibration.
PulsatingStraight lineIt does not rotate. Main winding alone, aligned axes, or no phase shift. At standstill it does not start; once running, it keeps turning.

Phase shift of each motor type

The values the tool sets are approximate, to show the difference between motors. The real phase shift depends on the resistance and inductance of each winding and on the capacitor. You can move them by hand.

MotorPhase shift setCentrifugal switch
Permanent capacitor90°No: the auxiliary stays connected
Start capacitor80°Yes: it disconnects the auxiliary
Start and run capacitors90°Yes: it only removes the start capacitor
Split phase30°Yes: it disconnects the auxiliary

With the centrifugal switch open, tick the box to see what remains: a pulsating field. The motor keeps turning because the running rotor creates the missing field, and that is something this simulation does not calculate.

Reversing the rotation

Press Swap Z1 and Z2: the field moves the other way, with the same shape. On the motor this is done in the terminal box, swapping the two ends of the auxiliary (or those of the main, but not both). If the winding brings out only three leads, it cannot be reversed without opening it.

Limits of the simulation. It only considers where the conductors are, plus the phase shift and strength you choose; it does not calculate the motor, the turns or the capacitor. Each arrow counts as one conductor, which is why the auxiliary strength is chosen separately. It uses the fundamental wave and does not see harmonics. Always measure the currents on the real motor.