EN

Synchronous machine checker

The rotor following the field: poles, voltages, load angle and excitation

Draw the stator arrows and the rotor poles, or import a diagram from Synchronous machine windings, and see whether they match and how the machine works. You start with an example of 24 slots and 4 poles.

Stator above, rotor below. Draw each conductor with the direction of its positive current. Click a rotor pole to swap N and S.

Simulation
E relative to the mains voltage
Active power, per unit
Per unit; 1 is a usual value
Voltage on U
Voltage on V
Voltage on W
Load angle δ
Current (p.u.)
cos φ
Power against δ: dashes, the load; dot, the working point. Beyond 90° synchronism is lost.
V curve at this load: the minimum is cos φ = 1. To the left, under-excited; to the right, over-excited.
Drawing
Changing them makes them alternate again
Phase arrow
Direction of rotation

Swap two mains phases. That is what reverses the rotation. Press again to undo it.

What it is for

In a synchronous machine the winding alone is not enough: stator and rotor must match. Here you see the rotor following the field at the same speed, at the angle the load demands. It checks the winding and shows what happens when excitation or load changes.

How to use it

  1. Enter the slots and rotor poles, or load an example or a diagram.
  2. Click each slot: in the top half the arrow goes up, in the bottom half down. Erase or a right click removes it.
  3. Choose motor or alternator and move the excitation and load.
  4. Press Animate, advance with Step +30° or move the angle, and read the diagnosis under the drawing.

What it checks

Why N and S appear elsewhere here

Rotating field and the single-phase checker put N where the upward current dominates, to follow how the arrows advance. Here, the stator's N and S are the real magnetic poles, 90 electrical degrees from that point: between the upward and downward bands. That is what faces the rotor. The advance is the same, and with no load each rotor N sits right opposite a stator S.

How to read the working point

Motor: the rotor runs behind the field by the load angle δ. Alternator: ahead of it. It is worked out as a cylindrical rotor: P = E·U·sin δ / Xs, with the mains voltage as 1.

ExcitationReactive powerWhat it means
Under-excitedAbsorbsMore current and less margin: it pulls out sooner.
cos φ = 1Neither absorbs nor deliversThe lowest current for that load: the bottom of the V.
Over-excitedDeliversIt improves the installation's cos φ and withstands peaks better. With no load, it is a synchronous compensator.
Limits of the simulation. It uses the fundamental wave, with each arrow as one conductor, and the voltage relative to a perfect winding and rotor. The working point is that of a cylindrical rotor with no resistance, at constant voltage: it does not see salient-pole reluctance torque, saturation, starting or oscillations. Per-unit values are not those of your machine. It is for checking the winding and understanding the behaviour, not for designing a real motor.