Stator and rotor of synchronous motors and alternators
| Option | Where it is used | What it is like |
|---|---|---|
| Distributed stator | Conventional motors and alternators | Three-phase in slots, the same as an induction motor |
| Tooth coils | Servomotors and permanent-magnet motors | Each coil goes round a single tooth: very short end turns |
| Salient-pole rotor | Generator sets, hydro and most synchronous motors | One concentrated coil per pole, all in series |
| Cylindrical rotor | 2- and 4-pole turbo-alternators | Concentric coils in slots, with the centre of each pole unslotted |
Here the coil pitch is always one slot and q is usually below 1. The rotor poles are not what the stator seems to give: a 12-slot stator works equally well with 10 or 14 magnets. So here the rotor sets the poles; they are not deduced from the arrows.
The method: each coil has an electrical angle, which is its tooth number times p·360°/Z. That angle places it in one of six 60° bands, which give its phase and direction: +U, −W, +V, −U, +W, −V. If the three phases do not come out equal and 120° apart, the combination is rejected.
| Slots / poles | q | Factor, double layer | Factor, single layer |
|---|---|---|---|
| 6 / 4 | 0.5 | 0.866 | 0.866 |
| 9 / 8 | 0.375 | 0.945 | — |
| 9 / 10 | 0.3 | 0.945 | — |
| 12 / 8 | 0.5 | 0.866 | 0.866 |
| 12 / 10 | 0.4 | 0.933 | 0.966 |
| 12 / 14 | 0.286 | 0.933 | 0.966 |
| 18 / 16 | 0.375 | 0.945 | 0.945 |
| 24 / 22 | 0.364 | 0.949 | 0.958 |
All coils are wound alike and connected so that the poles alternate. So the bridges join end to end and start to start. The diagram is seen from outside: current going down on the left and up on the right gives an N. Keep the turns, wire size and winding direction.
Divisions are the positions round the circumference. Those with no arrow are the pole centre: that iron is not slotted. Each pole has its concentric coils around that centre. With about 2/3 of the pole pitch occupied, the field wave comes quite close to a sine.
The rotor is fed with direct current through F1 (+) and F2 (−), by slip rings and brushes or rotating diodes. Connected directly to the mains, a synchronous motor does not start by itself: it starts as an induction motor on the damper winding, with the excitation closed through a resistor, or with a drive. Near synchronism the excitation is applied and the rotor pulls in. The damper is a cage of bars: it is not drawn here.
More explanation in the guide Synchronous machine fundamentals.