EN

Two-winding motors

Two speeds in any ratio, with independent windings

How they work

A two-speed motor with separate windings has two independent three-phase windings in the same stator slots, each with its own number of poles. Only one works at a time: the other stays disconnected. As it does not rely on reversing half-phases like the Dahlander, the speed ratio can be anything.

PolesSynchronous speed at 50 HzTypical uses
4 / 61500 / 1000 rpmFans, belt conveyors
6 / 81000 / 750 rpmCooling tower fans, mixers
2 / 83000 / 750 rpmCentrifuges, industrial washing machines (wash and spin)
4 / 161500 / 375 rpmHoisting: slow creep speed

Terminals and circuit

L1L2L3KM1F11U1V1WKM2F22U2V2WM 3~
Each winding has its own contactor and overload relay. The two must never be energised at the same time.

According to IEC 60034-8, in multi-speed motors the number before the letter indicates the speed, in increasing order: 1U-1V-1W is the winding for the low speed and 2U-2V-2W the one for the high speed. Each winding is usually star-connected internally, so the box has six terminals and no links:

SpeedSupply L1-L2-L3 toFree terminals
Low1U - 1V - 1W2U - 2V - 2W (insulated)
High2U - 2V - 2W1U - 1V - 1W (insulated)

Why the idle winding must stay open

The rotating field of the working winding also passes through the other one and induces voltages in its coils. If the idle winding formed a closed circuit, such as a delta, and those voltages did not cancel around the circuit, a current would flow in it, heating it and braking the motor. Therefore:

Power and size

The two windings share the slot area, so each one has less copper than the winding of a single-speed motor of the same frame size. As a result, each speed gives considerably less power than that motor, with lower efficiency and power factor. In return, each winding is designed with the best pitch and number of turns for its pole number, which the Dahlander cannot do.

Dahlander or separate windings

DahlanderSeparate windings
Speed ratio1:2 onlyAny
WindingsOne, with centre tapsTwo independent ones
Slot utilisationAll the copper works at both speedsEach speed uses only its own winding
Power for the same frame sizeHigherLower
Contactors32
Terminals66 (more if there are deltas)
Coil pitchCompromise between both pole numbersOptimal for each winding

Three- and four-speed motors

Combining both systems gives more speeds:

Here the closed-circuit problem appears again: the delta of an idle Dahlander winding must be left open while the other winding runs. That is why these motors have more terminals or a particular connection diagram. In every case, follow the diagram on the nameplate or inside the terminal box cover.

When rewinding