Two speeds in any ratio, with independent windings
A two-speed motor with separate windings has two independent three-phase windings in the same stator slots, each with its own number of poles. Only one works at a time: the other stays disconnected. As it does not rely on reversing half-phases like the Dahlander, the speed ratio can be anything.
| Poles | Synchronous speed at 50 Hz | Typical uses |
|---|---|---|
| 4 / 6 | 1500 / 1000 rpm | Fans, belt conveyors |
| 6 / 8 | 1000 / 750 rpm | Cooling tower fans, mixers |
| 2 / 8 | 3000 / 750 rpm | Centrifuges, industrial washing machines (wash and spin) |
| 4 / 16 | 1500 / 375 rpm | Hoisting: slow creep speed |
According to IEC 60034-8, in multi-speed motors the number before the letter indicates the speed, in increasing order: 1U-1V-1W is the winding for the low speed and 2U-2V-2W the one for the high speed. Each winding is usually star-connected internally, so the box has six terminals and no links:
| Speed | Supply L1-L2-L3 to | Free terminals |
|---|---|---|
| Low | 1U - 1V - 1W | 2U - 2V - 2W (insulated) |
| High | 2U - 2V - 2W | 1U - 1V - 1W (insulated) |
The rotating field of the working winding also passes through the other one and induces voltages in its coils. If the idle winding formed a closed circuit, such as a delta, and those voltages did not cancel around the circuit, a current would flow in it, heating it and braking the motor. Therefore:
The two windings share the slot area, so each one has less copper than the winding of a single-speed motor of the same frame size. As a result, each speed gives considerably less power than that motor, with lower efficiency and power factor. In return, each winding is designed with the best pitch and number of turns for its pole number, which the Dahlander cannot do.
| Dahlander | Separate windings | |
|---|---|---|
| Speed ratio | 1:2 only | Any |
| Windings | One, with centre taps | Two independent ones |
| Slot utilisation | All the copper works at both speeds | Each speed uses only its own winding |
| Power for the same frame size | Higher | Lower |
| Contactors | 3 | 2 |
| Terminals | 6 | 6 (more if there are deltas) |
| Coil pitch | Compromise between both pole numbers | Optimal for each winding |
Combining both systems gives more speeds:
Here the closed-circuit problem appears again: the delta of an idle Dahlander winding must be left open while the other winding runs. That is why these motors have more terminals or a particular connection diagram. In every case, follow the diagram on the nameplate or inside the terminal box cover.