Micrometer, resistance and weight, and how much enamel to subtract depending on diameter and grade
Before looking for equivalent wires or ordering wire, you need to know the copper diameter in the winding. A small measuring error shows up strongly in the cross-section, because it goes with the square of the diameter: mistaking a 0.50 mm wire for a 0.55 mm one is a 21 % difference in copper. The most common mistake is to measure the wire with its enamel and take that as the copper diameter, or to always subtract the same amount.
| Instrument | What it is good for |
|---|---|
| Outside micrometer (0.01 mm) | The right tool. For wire under 0.2 mm, a 0.001 mm micrometer is better, because one hundredth is already 5 % of the diameter. |
| Caliper | Even if it shows hundredths, its real accuracy is about ±0.02 to ±0.03 mm. Fine as a rough guide on thick wire, not to tell 0.50 from 0.53. |
| Wire gauge plate (slotted plate) | Gives the AWG or SWG gauge of bare wire. Enamelled wire only just fits the next thicker slot, so it errs upwards. |
| Ohmmeter or bridge | Gives the copper cross-section regardless of the enamel. Needs a long length and good low-resistance measurement. |
| Precision scale | With a known length it gives the cross-section. Useful with fine wire in large quantities. |
Without a micrometer, wind 20 turns close together on a bolt, measure the length with a caliper and divide by 20. The caliper error is shared among the turns. The result is the diameter over the enamel and comes out a little large, because there are always small gaps between turns.
There are two ways, and both work if done properly:
The enamel has neither a fixed thickness nor a fixed percentage of the diameter. IEC 60317 sets, for each nominal diameter, the minimum increase and the maximum overall diameter, and both grow with the diameter, but much more slowly. That is why on fine wire the enamel is a large part of the diameter and on thick wire a small one.
There are also three enamel grades. The higher the grade, the more coats and the more insulation:
The grades do not overlap: the overall diameter of grade 2 starts where grade 1 ends. In the American NEMA MW 1000 standard, single build, heavy build and triple build correspond roughly to grades 1, 2 and 3.
| Nominal (mm) | Grade 1 (mm) | Grade 2 (mm) | Grade 3 (mm) | Max. increase, grade 2 |
|---|---|---|---|---|
| 0.10 | 0.108 – 0.117 | 0.118 – 0.125 | 0.126 – 0.132 | 25 % |
| 0.20 | 0.214 – 0.226 | 0.227 – 0.239 | 0.240 – 0.252 | 19.5 % |
| 0.30 | 0.319 – 0.334 | 0.335 – 0.352 | 0.353 – 0.369 | 17.3 % |
| 0.40 | 0.421 – 0.439 | 0.440 – 0.459 | 0.460 – 0.478 | 14.8 % |
| 0.50 | 0.524 – 0.544 | 0.545 – 0.566 | 0.567 – 0.587 | 13.2 % |
| 0.71 | ≈ 0.738 – 0.762 | ≈ 0.763 – 0.789 | ≈ 0.790 – 0.813 | ≈ 11 % |
| 1.00 | ≈ 1.032 – 1.062 | ≈ 1.063 – 1.094 | ≈ 1.095 – 1.121 | ≈ 9.4 % |
| 1.50 | ≈ 1.535 – 1.570 | ≈ 1.571 – 1.606 | ≈ 1.607 – 1.637 | ≈ 7.1 % |
| 2.00 | ≈ 2.038 – 2.074 | ≈ 2.075 – 2.112 | ≈ 2.113 – 2.144 | ≈ 5.6 % |
Overall diameters over the enamel, from minimum to maximum. Up to 0.50 mm, from a wire maker's IEC 60317 data sheet; above that, approximate values from the same standard. Each maker works within these limits: if you have the reel, its label or data sheet takes precedence.
That is why fixed workshop rules fail:
A motor has wire measuring 0.56 mm over the enamel. Subtracting 0.05 mm would give 0.51 mm. With the table, 0.56 falls in grade 2 of 0.50 mm (0.545 to 0.566), and also in grade 1 of 0.53 mm. Grade 2 is normal in a motor and 0.53 is rare in workshops, so the wire is 0.50 mm. To make sure, 10 m of 0.50 mm wire should read about 0.88 Ω at 20 °C, and 0.53 mm about 0.78 Ω.
Resistance depends only on the copper, so the enamel has no effect. Measure a long, known length, such as a 10 m coil or a coil whose length you know, and work out the cross-section:
\[ S = \frac{\rho_{20}\, L}{R_{20}} \qquad d = \sqrt{\frac{4\,S}{\pi}} \]
With ρ20 = 0.017241 Ω·mm²/m, the resistivity of copper at 20 °C, L in metres and R in ohms.
If the wire is not at 20 °C, correct the resistance first:
\[ R_{20} = \frac{R_T}{1 + 0.00393\,(T - 20)} \]
For example, 10 m reading 0.900 Ω at 25 °C: R20 = 0.883 Ω, S = 0.195 mm² and d = 0.499 mm. It is 0.50 mm wire.
On short lengths the resistance is so low that the meter leads matter a lot. Short the probes and subtract the reading, or use a four-wire meter. Scrape the enamel off the ends for good contact.
Copper weighs 8.89 g/cm³. With the length in metres and the mass in grams:
\[ S\,(\text{mm}^2) = \frac{m}{8.89\, L} \]
The enamel also has weight, so the cross-section comes out somewhat high: very little on thick wire and quite a lot on fine wire. It is useful to find the gauge of a coil whose weight and length you know, or the other way round, to estimate how much wire is left on a reel.
The AWG gauge refers to bare copper, just like the IEC diameter. AWG 24 wire has 0.511 mm of copper; with heavy build enamel it measures about 0.55 to 0.56 mm, which can be mistaken for AWG 23 if the enamel is not subtracted. To go from copper diameter to gauge:
\[ n = 36 - 39\,\frac{\ln(d/0.127)}{\ln 92} \]
Each gauge changes the cross-section by 26 %, and three gauges double or halve it. Getting the gauge wrong is a bigger mistake than being one hundredth out in metric.