EN

Specifications of 4-pole three-phase motors

Typical technical data for 4-pole three-phase squirrel-cage induction motors (1500 rpm synchronous speed at 50 Hz), from 0.125 kW to 100 kW: speed, efficiency, power factor, current, torques, starting current, moment of inertia and weight.

How many rpm does a 4-pole motor run at? Its synchronous speed is 1500 rpm at 50 Hz and 1800 rpm at 60 Hz (n = 120 · f / poles). On load it runs a little slower because of slip: from the table, 1415 to 1485 rpm at 50 Hz, about 1450 rpm for medium sizes, and about 1740 rpm at 60 Hz.

Full-load values, three-phase supply 380 V / 50 Hz
Power Full-load characteristics Rated torque Starting torque Breakdown torque Starting I Moment of inertia Weight
kW hp rpm Efficiency (%) cos φ A a 380 V Nm Nm Nm A kg·m² kg
0.1250.17141569.50.70.390.841.62.11.60.0000709
0.20.27141572.50.730.581.352.63.42.50.0001410
0.330.45141574.50.760.92.234.25.64.00.0003011
0.50.7141576.50.791.253.376.48.45.60.0005712
0.81.1141679.50.81.95.401013.58.70.001215
1.11.5141679.50.82.57.421418.5120.001918
1.52141680.50.823.610.121925.3170.003022
2.23141781.50.825.114.832837.1250.005428
341417820.836.720.223850.5340.008736
45.5141883.50.848.726.95167.4440.01445
4.86.51418840.8410.332.36180.8540.01852
5.57.5141984.50.8411.837.07092.5630.02259
6.258.51419850.8413.242.180105710.02765
7.5101420850.8415.850.496126870.03577
11151423870.84522.273.81401851240.063109
15201426880.84529.2100.51912511660.10146
18.5251428880.8535.8123.72353092080.14178
2230143088.50.8543146.92793672540.18211
25.835143388.50.8552171.93274303120.23246
3041143688.50.8562199.53794993780.29284
34461439890.8570.5225.74295644370.35321
37501441890.8674.8245.24666134710.40349
40541443890.8680.5264.75036625150.45377
44.5601446890.86589.5293.95587355820.53418
50681450890.87102329.36268236730.63469
55.5751454890.88109364.66939117300.74520
59801456890.88117386.97359677960.81552
6284145889.50.88122406.077110108420.87580
801101471900.88155519.4987129010801.28745
1001361485910.89190643.11220160013401.80930

On mobile, swipe the table sideways to see all the columns.

How to read the table

ColumnMeaning
kW / hpUseful mechanical power at the shaft. 1 hp (metric) = 0.736 kW.
rpmActual full-load speed. It is slightly lower than the synchronous speed (1500 rpm at 50 Hz) because of slip.
EfficiencyRatio between the mechanical power delivered and the electrical power drawn.
cos φFull-load power factor. It shows how much reactive energy the motor draws.
A a 380 VRated current per phase with a 380 V three-phase supply.
Rated torqueShaft torque at full load and rated speed.
Starting torqueTorque delivered by the motor at standstill when switched on. It must exceed the load torque.
Breakdown torqueHighest torque the motor can deliver before it stalls.
Starting ICurrent peak during direct-on-line starting, usually 5 to 8 times the rated current.
Moment of inertiaRotor inertia. Used to calculate starting and braking times.
WeightApproximate weight of the motor with a standard frame.

Related formulas

Rated torque from power and speed:

M (Nm) = 9550 · P (kW) / n (rpm)

Rated current of a three-phase motor:

I = P · 1000 / (√3 · V · η · cos φ)

Current at another voltage (for example, 400 V instead of 380 V):

I400 ≈ I380 · 380 / 400

Slip:

s (%) = (ns − n) / ns · 100, with ns = 120 · f / p = 1500 rpm (4 poles, 50 Hz)

Worked example

A 7.5 kW, 1420 rpm motor has a rated torque of 9550 · 7.5 / 1420 ≈ 50.4 Nm, the value in the table. That is about twice the torque of a 2-pole motor of the same power, because it runs at half the speed. At 380 V it draws about 15.8 A; at 400 V it would be about 15 A. On direct-on-line starting it will draw around 87 A, about 5.5 times the rated current, something to bear in mind when choosing the protection and starting method.

When to use a 4-pole motor?

The 4-pole motor is the most widely used in industry. Its speed of about 1450 rpm suits most gearboxes, conveyors, pumps, compressors, mixers and machines in general. It offers a good balance between torque, size, price and bearing life, and compared with a 2-pole motor of the same power it delivers twice the torque and runs more quietly.

Typical approximate values for general-purpose motors. Each manufacturer and series (IE1, IE2, IE3…) has its own data: always check the nameplate and the manufacturer's catalogue.