Typical technical data for 4-pole three-phase squirrel-cage induction motors (1500 rpm synchronous speed at 50 Hz), from 0.125 kW to 100 kW: speed, efficiency, power factor, current, torques, starting current, moment of inertia and weight.
How many rpm does a 4-pole motor run at? Its synchronous speed is 1500 rpm at 50 Hz and 1800 rpm at 60 Hz (n = 120 · f / poles). On load it runs a little slower because of slip: from the table, 1415 to 1485 rpm at 50 Hz, about 1450 rpm for medium sizes, and about 1740 rpm at 60 Hz.
| Power | Full-load characteristics | Rated torque | Starting torque | Breakdown torque | Starting I | Moment of inertia | Weight | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| kW | hp | rpm | Efficiency (%) | cos φ | A a 380 V | Nm | Nm | Nm | A | kg·m² | kg |
| 0.125 | 0.17 | 1415 | 69.5 | 0.7 | 0.39 | 0.84 | 1.6 | 2.1 | 1.6 | 0.000070 | 9 |
| 0.2 | 0.27 | 1415 | 72.5 | 0.73 | 0.58 | 1.35 | 2.6 | 3.4 | 2.5 | 0.00014 | 10 |
| 0.33 | 0.45 | 1415 | 74.5 | 0.76 | 0.9 | 2.23 | 4.2 | 5.6 | 4.0 | 0.00030 | 11 |
| 0.5 | 0.7 | 1415 | 76.5 | 0.79 | 1.25 | 3.37 | 6.4 | 8.4 | 5.6 | 0.00057 | 12 |
| 0.8 | 1.1 | 1416 | 79.5 | 0.8 | 1.9 | 5.40 | 10 | 13.5 | 8.7 | 0.0012 | 15 |
| 1.1 | 1.5 | 1416 | 79.5 | 0.8 | 2.5 | 7.42 | 14 | 18.5 | 12 | 0.0019 | 18 |
| 1.5 | 2 | 1416 | 80.5 | 0.82 | 3.6 | 10.12 | 19 | 25.3 | 17 | 0.0030 | 22 |
| 2.2 | 3 | 1417 | 81.5 | 0.82 | 5.1 | 14.83 | 28 | 37.1 | 25 | 0.0054 | 28 |
| 3 | 4 | 1417 | 82 | 0.83 | 6.7 | 20.22 | 38 | 50.5 | 34 | 0.0087 | 36 |
| 4 | 5.5 | 1418 | 83.5 | 0.84 | 8.7 | 26.9 | 51 | 67.4 | 44 | 0.014 | 45 |
| 4.8 | 6.5 | 1418 | 84 | 0.84 | 10.3 | 32.3 | 61 | 80.8 | 54 | 0.018 | 52 |
| 5.5 | 7.5 | 1419 | 84.5 | 0.84 | 11.8 | 37.0 | 70 | 92.5 | 63 | 0.022 | 59 |
| 6.25 | 8.5 | 1419 | 85 | 0.84 | 13.2 | 42.1 | 80 | 105 | 71 | 0.027 | 65 |
| 7.5 | 10 | 1420 | 85 | 0.84 | 15.8 | 50.4 | 96 | 126 | 87 | 0.035 | 77 |
| 11 | 15 | 1423 | 87 | 0.845 | 22.2 | 73.8 | 140 | 185 | 124 | 0.063 | 109 |
| 15 | 20 | 1426 | 88 | 0.845 | 29.2 | 100.5 | 191 | 251 | 166 | 0.10 | 146 |
| 18.5 | 25 | 1428 | 88 | 0.85 | 35.8 | 123.7 | 235 | 309 | 208 | 0.14 | 178 |
| 22 | 30 | 1430 | 88.5 | 0.85 | 43 | 146.9 | 279 | 367 | 254 | 0.18 | 211 |
| 25.8 | 35 | 1433 | 88.5 | 0.85 | 52 | 171.9 | 327 | 430 | 312 | 0.23 | 246 |
| 30 | 41 | 1436 | 88.5 | 0.85 | 62 | 199.5 | 379 | 499 | 378 | 0.29 | 284 |
| 34 | 46 | 1439 | 89 | 0.85 | 70.5 | 225.7 | 429 | 564 | 437 | 0.35 | 321 |
| 37 | 50 | 1441 | 89 | 0.86 | 74.8 | 245.2 | 466 | 613 | 471 | 0.40 | 349 |
| 40 | 54 | 1443 | 89 | 0.86 | 80.5 | 264.7 | 503 | 662 | 515 | 0.45 | 377 |
| 44.5 | 60 | 1446 | 89 | 0.865 | 89.5 | 293.9 | 558 | 735 | 582 | 0.53 | 418 |
| 50 | 68 | 1450 | 89 | 0.87 | 102 | 329.3 | 626 | 823 | 673 | 0.63 | 469 |
| 55.5 | 75 | 1454 | 89 | 0.88 | 109 | 364.6 | 693 | 911 | 730 | 0.74 | 520 |
| 59 | 80 | 1456 | 89 | 0.88 | 117 | 386.9 | 735 | 967 | 796 | 0.81 | 552 |
| 62 | 84 | 1458 | 89.5 | 0.88 | 122 | 406.0 | 771 | 1010 | 842 | 0.87 | 580 |
| 80 | 110 | 1471 | 90 | 0.88 | 155 | 519.4 | 987 | 1290 | 1080 | 1.28 | 745 |
| 100 | 136 | 1485 | 91 | 0.89 | 190 | 643.1 | 1220 | 1600 | 1340 | 1.80 | 930 |
On mobile, swipe the table sideways to see all the columns.
| Column | Meaning |
|---|---|
| kW / hp | Useful mechanical power at the shaft. 1 hp (metric) = 0.736 kW. |
| rpm | Actual full-load speed. It is slightly lower than the synchronous speed (1500 rpm at 50 Hz) because of slip. |
| Efficiency | Ratio between the mechanical power delivered and the electrical power drawn. |
| cos φ | Full-load power factor. It shows how much reactive energy the motor draws. |
| A a 380 V | Rated current per phase with a 380 V three-phase supply. |
| Rated torque | Shaft torque at full load and rated speed. |
| Starting torque | Torque delivered by the motor at standstill when switched on. It must exceed the load torque. |
| Breakdown torque | Highest torque the motor can deliver before it stalls. |
| Starting I | Current peak during direct-on-line starting, usually 5 to 8 times the rated current. |
| Moment of inertia | Rotor inertia. Used to calculate starting and braking times. |
| Weight | Approximate weight of the motor with a standard frame. |
Rated torque from power and speed:
Rated current of a three-phase motor:
Current at another voltage (for example, 400 V instead of 380 V):
Slip:
A 7.5 kW, 1420 rpm motor has a rated torque of 9550 · 7.5 / 1420 ≈ 50.4 Nm, the value in the table. That is about twice the torque of a 2-pole motor of the same power, because it runs at half the speed. At 380 V it draws about 15.8 A; at 400 V it would be about 15 A. On direct-on-line starting it will draw around 87 A, about 5.5 times the rated current, something to bear in mind when choosing the protection and starting method.
The 4-pole motor is the most widely used in industry. Its speed of about 1450 rpm suits most gearboxes, conveyors, pumps, compressors, mixers and machines in general. It offers a good balance between torque, size, price and bearing life, and compared with a 2-pole motor of the same power it delivers twice the torque and runs more quietly.
Typical approximate values for general-purpose motors. Each manufacturer and series (IE1, IE2, IE3…) has its own data: always check the nameplate and the manufacturer's catalogue.