Typical technical data for 6-pole three-phase squirrel-cage induction motors (1000 rpm synchronous speed at 50 Hz), from 0.18 kW to 315 kW: speed, efficiency, power factor, current, torques, starting current, moment of inertia and weight.
How many rpm does a 6-pole motor run at? Its synchronous speed is 1000 rpm at 50 Hz and 1200 rpm at 60 Hz (n = 120 · f / poles). On load it runs a little slower because of slip: from the table, 860 to 990 rpm at 50 Hz, about 960 rpm for medium sizes, and about 1150 rpm at 60 Hz.
| Power | Full-load characteristics | Rated torque | Starting torque | Breakdown torque | Starting I | Moment of inertia | Weight | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| kW | hp | rpm | Efficiency (%) | cos φ | A a 380 V | Nm | Nm | Nm | A | kg·m² | kg |
| 0.18 | 0.25 | 860 | 54 | 0.7 | 0.72 | 2.0 | 3 | 4 | 1.8 | 0.0007 | 8.5 |
| 0.25 | 0.34 | 870 | 56 | 0.7 | 1 | 2.7 | 4 | 6 | 2.6 | 0.0009 | 9.5 |
| 0.37 | 0.5 | 880 | 65 | 0.7 | 1.25 | 4.0 | 6 | 8 | 3.8 | 0.0018 | 12 |
| 0.55 | 0.75 | 880 | 68 | 0.7 | 1.75 | 6.0 | 9 | 12 | 5.3 | 0.0021 | 13.5 |
| 0.75 | 1 | 915 | 68 | 0.73 | 2.3 | 7.8 | 13 | 16 | 9.2 | 0.0032 | 19 |
| 1.1 | 1.5 | 920 | 70 | 0.74 | 3.1 | 11 | 19 | 24 | 12 | 0.0039 | 23 |
| 1.5 | 2 | 935 | 75 | 0.78 | 3.9 | 15 | 26 | 33 | 18 | 0.008 | 32 |
| 2.2 | 3 | 935 | 78 | 0.78 | 5.5 | 22 | 38 | 48 | 26 | 0.01 | 40 |
| 3 | 4 | 945 | 83 | 0.78 | 7 | 30 | 53 | 66 | 35 | 0.026 | 54 |
| 4 | 5.5 | 950 | 83 | 0.78 | 9.4 | 40 | 71 | 88 | 50 | 0.029 | 62 |
| 5.5 | 7.5 | 950 | 84 | 0.78 | 12.7 | 55 | 99 | 123 | 71 | 0.0375 | 71 |
| 7.5 | 10 | 960 | 85 | 0.8 | 17 | 75 | 136 | 167 | 94 | 0.072 | 110 |
| 11 | 15 | 960 | 86 | 0.8 | 24 | 109 | 203 | 248 | 132 | 0.1 | 137 |
| 15 | 20 | 965 | 88 | 0.82 | 31.5 | 140 | 263 | 320 | 173 | 0.16 | 175 |
| 18.5 | 25 | 975 | 90 | 0.83 | 37 | 180 | 344 | 416 | 200 | 0.23 | 245 |
| 22 | 30 | 975 | 90 | 0.83 | 45 | 210 | 407 | 490 | 240 | 0.3 | 264 |
| 30 | 40 | 980 | 91.5 | 0.85 | 58 | 290 | 571 | 683 | 360 | 0.53 | 350 |
| 37 | 50 | 980 | 92 | 0.86 | 70.5 | 360 | 719 | 856 | 420 | 0.8 | 440 |
| 45 | 60 | 980 | 92.5 | 0.86 | 85 | 430 | 871 | 1032 | 530 | 1.5 | 625 |
| 55 | 75 | 980 | 92.5 | 0.87 | 103 | 530 | 1090 | 1284 | 640 | 1.8 | 680 |
| 75 | 100 | 985 | 93 | 0.88 | 140 | 720 | 1501 | 1760 | 910 | 2.85 | 840 |
| 90 | 125 | 985 | 93.5 | 0.88 | 166 | 870 | 1839 | 2146 | 1090 | 3.4 | 935 |
| 110 | 150 | 985 | 94 | 0.89 | 200 | 1060 | 2272 | 2638 | 1340 | 4.35 | 1200 |
| 132 | 180 | 985 | 94.5 | 0.89 | 240 | 1280 | 2781 | 3213 | 1600 | 4.85 | 1300 |
| 160 | 220 | 985 | 94.5 | 0.89 | 290 | 1550 | 3413 | 3926 | 1910 | 8 | 1450 |
| 200 | 270 | 990 | 95 | 0.89 | 360 | 1920 | 4284 | 4906 | 2370 | 10 | 1700 |
| 250 | 340 | 990 | 95 | 0.89 | 448 | 2410 | 5448 | 6211 | 3000 | 17 | 2100 |
| 315 | 430 | 990 | 95 | 0.89 | 567 | 3030 | 6938 | 7876 | 3790 | 21 | 2450 |
On mobile, swipe the table sideways to see all the columns.
| Column | Meaning |
|---|---|
| kW / hp | Useful mechanical power at the shaft. 1 hp (metric) = 0.736 kW. |
| rpm | Actual full-load speed. It is slightly lower than the synchronous speed (1000 rpm at 50 Hz) because of slip. |
| Efficiency | Ratio between the mechanical power delivered and the electrical power drawn. |
| cos φ | Full-load power factor. It shows how much reactive energy the motor draws. |
| A a 380 V | Rated current per phase with a 380 V three-phase supply. |
| Rated torque | Shaft torque at full load and rated speed. |
| Starting torque | Torque delivered by the motor at standstill when switched on. It must exceed the load torque. |
| Breakdown torque | Highest torque the motor can deliver before it stalls. |
| Starting I | Current peak during direct-on-line starting, usually 5 to 8 times the rated current. |
| Moment of inertia | Rotor inertia. Used to calculate starting and braking times. |
| Weight | Approximate weight of the motor with a standard frame. |
Rated torque from power and speed:
Rated current of a three-phase motor:
Current at another voltage (for example, 400 V instead of 380 V):
Slip:
A 7.5 kW, 960 rpm motor has a rated torque of 9550 · 7.5 / 960 ≈ 75 Nm, the value in the table. That is about three times the torque of a 2-pole motor of the same power, because it runs at a third of its speed. At 380 V it draws about 17 A; at 400 V it would be about 16.2 A. On direct-on-line starting it will draw around 94 A, about 5.5 times the rated current, something to bear in mind when choosing the protection and starting method.
6-pole motors run at about 950–990 rpm. They are chosen when the machine needs low speed and high torque: mills, crushers, heavy conveyors, large low-speed fans, mixers or cranes. They allow smaller gearboxes or none at all. In return, for the same power they are larger, heavier and more expensive than a 4-pole motor and usually have a slightly lower cos φ.
Typical approximate values for general-purpose motors. Each manufacturer and series (IE1, IE2, IE3…) has its own data: always check the nameplate and the manufacturer's catalogue.