Typical technical data for 6-pole three-phase squirrel-cage induction motors (1000 rpm synchronous speed at 50 Hz), from 0.18 kW to 315 kW: speed, efficiency, power factor, current, torques, starting current, moment of inertia and weight.

How many rpm does a 6-pole motor run at? Its synchronous speed is 1000 rpm at 50 Hz and 1200 rpm at 60 Hz (n = 120 · f / poles). On load it runs a little slower because of slip: from the table, 860 to 990 rpm at 50 Hz, about 960 rpm for medium sizes, and about 1150 rpm at 60 Hz.

Full-load values, three-phase supply 380 V / 50 Hz
Power Full-load characteristics Rated torque Starting torque Breakdown torque Starting I Moment of inertia Weight
kW hp rpm Efficiency (%) cos φ A a 380 V Nm Nm Nm A kg·m² kg
0.180.25860540.70.722.0341.80.00078.5
0.250.34870560.712.7462.60.00099.5
0.370.5880650.71.254.0683.80.001812
0.550.75880680.71.756.09125.30.002113.5
0.751915680.732.37.813169.20.003219
1.11.5920700.743.1111924120.003923
1.52935750.783.9152633180.00832
2.23935780.785.5223848260.0140
34945830.787305366350.02654
45.5950830.789.4407188500.02962
5.57.5950840.7812.75599123710.037571
7.510960850.81775136167940.072110
1115960860.8241092032481320.1137
1520965880.8231.51402633201730.16175
18.525975900.83371803444162000.23245
2230975900.83452104074902400.3264
304098091.50.85582905716833600.53350
3750980920.8670.53607198564200.8440
456098092.50.868543087110325301.5625
557598092.50.87103530109012846401.8680
75100985930.88140720150117609102.85840
9012598593.50.881668701839214610903.4935
110150985940.8920010602272263813404.351200
13218098594.50.8924012802781321316004.851300
16022098594.50.89290155034133926191081450
200270990950.893601920428449062370101700
250340990950.894482410544862113000172100
315430990950.895673030693878763790212450

On mobile, swipe the table sideways to see all the columns.

How to read the table

ColumnMeaning
kW / hpUseful mechanical power at the shaft. 1 hp (metric) = 0.736 kW.
rpmActual full-load speed. It is slightly lower than the synchronous speed (1000 rpm at 50 Hz) because of slip.
EfficiencyRatio between the mechanical power delivered and the electrical power drawn.
cos φFull-load power factor. It shows how much reactive energy the motor draws.
A a 380 VRated current per phase with a 380 V three-phase supply.
Rated torqueShaft torque at full load and rated speed.
Starting torqueTorque delivered by the motor at standstill when switched on. It must exceed the load torque.
Breakdown torqueHighest torque the motor can deliver before it stalls.
Starting ICurrent peak during direct-on-line starting, usually 5 to 8 times the rated current.
Moment of inertiaRotor inertia. Used to calculate starting and braking times.
WeightApproximate weight of the motor with a standard frame.

Related formulas

Rated torque from power and speed:

M (Nm) = 9550 · P (kW) / n (rpm)

Rated current of a three-phase motor:

I = P · 1000 / (√3 · V · η · cos φ)

Current at another voltage (for example, 400 V instead of 380 V):

I400 ≈ I380 · 380 / 400

Slip:

s (%) = (ns − n) / ns · 100, with ns = 120 · f / p = 1000 rpm (6 poles, 50 Hz)

Worked example

A 7.5 kW, 960 rpm motor has a rated torque of 9550 · 7.5 / 960 ≈ 75 Nm, the value in the table. That is about three times the torque of a 2-pole motor of the same power, because it runs at a third of its speed. At 380 V it draws about 17 A; at 400 V it would be about 16.2 A. On direct-on-line starting it will draw around 94 A, about 5.5 times the rated current, something to bear in mind when choosing the protection and starting method.

When to use a 6-pole motor?

6-pole motors run at about 950–990 rpm. They are chosen when the machine needs low speed and high torque: mills, crushers, heavy conveyors, large low-speed fans, mixers or cranes. They allow smaller gearboxes or none at all. In return, for the same power they are larger, heavier and more expensive than a 4-pole motor and usually have a slightly lower cos φ.

Typical approximate values for general-purpose motors. Each manufacturer and series (IE1, IE2, IE3…) has its own data: always check the nameplate and the manufacturer's catalogue.