Z, Y, H and ABCD parameters, conversion between them, T and π networks and the loaded two-port
A two-port network is any circuit with one pair of input terminals and another pair of output terminals: a filter, a line, a transformer, an amplifier. Instead of analysing its interior, it is described by four numbers that relate the two voltages and the two currents at its ports. With them you can work out what happens when any source and any load are connected to it.
Sign convention: \(V_1, I_1\) at the input and \(V_2, I_2\) at the output, with both currents flowing into the two-port through the positive terminal. The parameters are linear: the two-port cannot contain independent sources and, for AC, everything is expressed in complex form at a given frequency.
| Parameters | Equations | Measured with | Useful for |
|---|---|---|---|
| Impedance Z | \(V_1 = Z_{11}I_1 + Z_{12}I_2\) \(V_2 = Z_{21}I_1 + Z_{22}I_2\) | Ports open-circuited | Series connection |
| Admittance Y | \(I_1 = Y_{11}V_1 + Y_{12}V_2\) \(I_2 = Y_{21}V_1 + Y_{22}V_2\) | Ports short-circuited | Parallel connection |
| Hybrid H | \(V_1 = H_{11}I_1 + H_{12}V_2\) \(I_2 = H_{21}I_1 + H_{22}V_2\) | Output shorted and input open | Transistors (hie, hfe…) |
| Transmission ABCD | \(V_1 = A\,V_2 - B\,I_2\) \(I_1 = C\,V_2 - D\,I_2\) | Output open and shorted | Cascades, power lines |
Each parameter is obtained by setting one variable to zero. For example, \(Z_{11} = V_1/I_1\) with \(I_2 = 0\) (output open) is the open-circuit input impedance, and \(Y_{21} = I_2/V_1\) with \(V_2 = 0\) (output shorted) is the transfer admittance. \(A\) is the open-circuit voltage ratio, \(B\) an impedance, \(C\) an admittance and \(D\) a short-circuit current ratio.
Going through the transmission parameters (\(\Delta_T = AD - BC\), \(\Delta_Z = Z_{11}Z_{22} - Z_{12}Z_{21}\)…):
A parameter set may not exist: for example, a series impedance has no Z parameters (\(C = 0\)) and a shunt one has no Y parameters (\(B = 0\)).
| Property | Z | Y | H | ABCD |
|---|---|---|---|---|
| Reciprocal (R, L, C and transformers only) | \(Z_{12} = Z_{21}\) | \(Y_{12} = Y_{21}\) | \(H_{12} = -H_{21}\) | \(AD - BC = 1\) |
| Symmetrical (can be turned around) | \(Z_{11} = Z_{22}\) | \(Y_{11} = Y_{22}\) | \(\Delta_H = 1\) | \(A = D\) |
A reciprocal two-port is defined by three values and can always be represented by an equivalent T or π network:
Adding Z, Y or H matrices is only valid if the connection does not alter the currents at each port (Brune test); for three-terminal networks with a common ground, such as the T and the π, it holds.
With a load \(Z_L\) at the output (\(V_2 = -Z_L I_2\)) and a source \(V_g\) with internal impedance \(Z_g\) at the input:
The image impedances are those which, placed at each port, make the two-port "see" the same impedance at the other. In a symmetrical two-port they coincide in the characteristic impedance \(Z_c\): loaded with \(Z_c\), its input is also \(Z_c\), just like a matched line.
| Set | 11 · A | 12 · B | 21 · C | 22 · D |
|---|
\(Z_a = Z_b = 10 + j20\ \Omega\) and \(Z_c = -j50\ \Omega\) (a capacitor), loaded with 50 Ω.
It satisfies \(AD - BC = (0.6 + j0.2)^2 - (12 + j34)(j0.02) = 1\): it is reciprocal, as a passive network should be. The calculator gives the rest.
Related: Thévenin and Norton · delta-star transformation · RLC circuit