EN

Two-port networks

Z, Y, H and ABCD parameters, conversion between them, T and π networks and the loaded two-port

1. What a two-port network is

A two-port network is any circuit with one pair of input terminals and another pair of output terminals: a filter, a line, a transformer, an amplifier. Instead of analysing its interior, it is described by four numbers that relate the two voltages and the two currents at its ports. With them you can work out what happens when any source and any load are connected to it.

Sign convention: \(V_1, I_1\) at the input and \(V_2, I_2\) at the output, with both currents flowing into the two-port through the positive terminal. The parameters are linear: the two-port cannot contain independent sources and, for AC, everything is expressed in complex form at a given frequency.

2. The four parameter sets

ParametersEquationsMeasured withUseful for
Impedance Z\(V_1 = Z_{11}I_1 + Z_{12}I_2\)
\(V_2 = Z_{21}I_1 + Z_{22}I_2\)
Ports open-circuitedSeries connection
Admittance Y\(I_1 = Y_{11}V_1 + Y_{12}V_2\)
\(I_2 = Y_{21}V_1 + Y_{22}V_2\)
Ports short-circuitedParallel connection
Hybrid H\(V_1 = H_{11}I_1 + H_{12}V_2\)
\(I_2 = H_{21}I_1 + H_{22}V_2\)
Output shorted and input openTransistors (hie, hfe…)
Transmission ABCD\(V_1 = A\,V_2 - B\,I_2\)
\(I_1 = C\,V_2 - D\,I_2\)
Output open and shortedCascades, power lines

Each parameter is obtained by setting one variable to zero. For example, \(Z_{11} = V_1/I_1\) with \(I_2 = 0\) (output open) is the open-circuit input impedance, and \(Y_{21} = I_2/V_1\) with \(V_2 = 0\) (output shorted) is the transfer admittance. \(A\) is the open-circuit voltage ratio, \(B\) an impedance, \(C\) an admittance and \(D\) a short-circuit current ratio.

3. Converting between parameters

Going through the transmission parameters (\(\Delta_T = AD - BC\), \(\Delta_Z = Z_{11}Z_{22} - Z_{12}Z_{21}\)…):

\[ \begin{pmatrix} A & B \\ C & D \end{pmatrix} = \frac{1}{Z_{21}}\begin{pmatrix} Z_{11} & \Delta_Z \\ 1 & Z_{22} \end{pmatrix} = \frac{-1}{Y_{21}}\begin{pmatrix} Y_{22} & 1 \\ \Delta_Y & Y_{11} \end{pmatrix} = \frac{-1}{H_{21}}\begin{pmatrix} \Delta_H & H_{11} \\ H_{22} & 1 \end{pmatrix} \]
\[ Z = \frac{1}{C}\begin{pmatrix} A & \Delta_T \\ 1 & D \end{pmatrix} \]\[ Y = \frac{1}{B}\begin{pmatrix} D & -\Delta_T \\ -1 & A \end{pmatrix} \]\[ H = \frac{1}{D}\begin{pmatrix} B & \Delta_T \\ -1 & C \end{pmatrix} \]

A parameter set may not exist: for example, a series impedance has no Z parameters (\(C = 0\)) and a shunt one has no Y parameters (\(B = 0\)).

4. Reciprocity and symmetry

PropertyZYHABCD
Reciprocal (R, L, C and transformers only)\(Z_{12} = Z_{21}\)\(Y_{12} = Y_{21}\)\(H_{12} = -H_{21}\)\(AD - BC = 1\)
Symmetrical (can be turned around)\(Z_{11} = Z_{22}\)\(Y_{11} = Y_{22}\)\(\Delta_H = 1\)\(A = D\)

A reciprocal two-port is defined by three values and can always be represented by an equivalent T or π network:

T network: \(Z_{11} = Z_a + Z_c\), \(Z_{12} = Z_{21} = Z_c\), \(Z_{22} = Z_b + Z_c\).
π network: \(Y_{11} = 1/Z_1 + 1/Z_2\), \(Y_{12} = Y_{21} = -1/Z_2\), \(Y_{22} = 1/Z_3 + 1/Z_2\).

5. Interconnecting two-ports

Adding Z, Y or H matrices is only valid if the connection does not alter the currents at each port (Brune test); for three-terminal networks with a common ground, such as the T and the π, it holds.

6. Loaded two-port

With a load \(Z_L\) at the output (\(V_2 = -Z_L I_2\)) and a source \(V_g\) with internal impedance \(Z_g\) at the input:

\[ Z_{in} = \frac{A\,Z_L + B}{C\,Z_L + D} \]\[ Z_{out} = \frac{D\,Z_g + B}{C\,Z_g + A} \]\[ \frac{V_2}{V_1} = \frac{Z_L}{A\,Z_L + B} \]\[ \frac{I_L}{I_1} = \frac{1}{C\,Z_L + D} \]
\[ Z_{i1} = \sqrt{\frac{A\,B}{C\,D}} \]\[ Z_{i2} = \sqrt{\frac{D\,B}{A\,C}} \]\[ Z_c = \sqrt{\frac{B}{C}}\ \text{(simétrico)} \]

The image impedances are those which, placed at each port, make the two-port "see" the same impedance at the other. In a symmetrical two-port they coincide in the characteristic impedance \(Z_c\): loaded with \(Z_c\), its input is also \(Z_c\), just like a matched line.

7. Calculator

Two-port
ValueReal partImaginary partUnit
Source and load
ValueReal partImaginary partUnit
Load ZLΩ
Source impedance ZgΩ
Source voltage Vg (RMS, angle 0°)–V

Parameters

Set11 · A12 · B21 · C22 · D

With the source and the load

Example: symmetrical T network

\(Z_a = Z_b = 10 + j20\ \Omega\) and \(Z_c = -j50\ \Omega\) (a capacitor), loaded with 50 Ω.

\[ A = D = 1 + \frac{Z_a}{Z_c} = 1 + \frac{10 + j20}{-j50} = 0.6 + j0.2 \qquad C = \frac{1}{Z_c} = j0.02\ \text{S} \]
\[ B = Z_a + Z_b + \frac{Z_a Z_b}{Z_c} = 20 + j40 + \frac{(10 + j20)^2}{-j50} = 12 + j34\ \Omega \]

It satisfies \(AD - BC = (0.6 + j0.2)^2 - (12 + j34)(j0.02) = 1\): it is reciprocal, as a passive network should be. The calculator gives the rest.

Related: Thévenin and Norton · delta-star transformation · RLC circuit