Convert IEC wire combinations to NEMA and vice versa
It moves a winding from one standard to the other: from AWG gauges (NEMA) to diameters in millimetres (IEC), or the other way round. You need it when an American motor arrives and you only have metric wire, or when you follow a diagram with data in the other standard. There is no exact equivalence between the two series, so it proposes combinations that match the copper section.
The exclusion list belongs to the output standard: if you enter AWG, you exclude diameters; if you enter metric, you exclude gauges.
The target section appears above the table. Each row gives the wires that go together, in mm if the output is metric or as an AWG number if it is NEMA, the section they add up to and the difference. If nothing appears, widen the tolerance.
The metric diameter in the last column is just the closest and does not have the same section. For a reliable result, calculate with the tool.
| AWG | Diameter (mm) | Section (mm²) | Nearest metric (mm) |
|---|---|---|---|
| 14 | 1.628 | 2.081 | 1.60 |
| 16 | 1.291 | 1.309 | 1.30 |
| 18 | 1.024 | 0.823 | 1.00 |
| 20 | 0.812 | 0.518 | 0.80 |
| 22 | 0.644 | 0.326 | 0.65 |
| 24 | 0.511 | 0.205 | 0.50 |
| 26 | 0.405 | 0.129 | 0.40 |
| 28 | 0.321 | 0.081 | 0.30 |
| 30 | 0.255 | 0.051 | 0.25 |