Swapping the source and the measuring point does not change the response of a passive circuit
In a circuit made only of resistors, inductors, capacitors and transformers, the influence of one point on another is the same in both directions. If a source placed in branch A produces a certain current in branch B, the same source moved to branch B produces that same current in branch A. It does not matter how complicated the circuit between them is.
| Form | Excitation | Response | Holds |
|---|---|---|---|
| Voltage – current | Voltage source \(E\) in a branch | Short-circuit current in another branch | \(\dfrac{I_2}{E_1} = \dfrac{I_1}{E_2}\) |
| Current – voltage | Current source \(I\) between two nodes | Open-circuit voltage between two other nodes | \(\dfrac{V_2}{I_1} = \dfrac{V_1}{I_2}\) |
| Mixed | Current source at one port / voltage source at the other | Short-circuit current / open-circuit voltage | \(\dfrac{I_2}{I_1} = -\dfrac{V_1}{V_2}\) |
In the first two forms, if the source has the same value in both cases, the response is exactly the same. In the mixed form a minus sign appears with the usual conventions (currents entering through the positive terminal of each port). In AC everything holds with phasors and complex impedances.
A T network of 2 Ω, 6 Ω and 3 Ω resistors. With a 12 V source on the left and the right side short-circuited:
Now the source moves to the right and the short circuit to the left:
The total current delivered by the source changes (3 A versus 2.667 A), but the current transferred to the other side is the same: 2 A.
In the same network, with a 1 A current source on the left and the right side open, no current flows through the 3 Ω resistor and the output voltage is that of the 6 Ω resistor: \(V_2 = 1 \cdot 6 = 6\) V. With the source on the right and the left side open, no current flows through the 2 Ω resistor either and \(V_1 = 6\) V. This is the parameter \(Z_{12} = Z_{21} = 6\,\Omega\) of the two-port network.
Coupled coils satisfy \(M_{12} = M_{21}\): the voltage that coil 1 induces in coil 2 per ampere is the same that coil 2 induces in coil 1. It is a particular case of reciprocity and the reason why a single mutual inductance \(M\) is used in coil coupling.
A reciprocal two-port network has one parameter fewer than an arbitrary one, because it satisfies:
That is why three measurements are enough (for example, open circuit and short circuit from the input and open circuit from the output), and why any passive network can be represented by an equivalent T or π. The open-circuit and short-circuit tests of a transformer rely on this property.
Related: two-port networks · Tellegen's theorem (it can be used to prove reciprocity) · Thévenin and Norton